...
首页> 外文期刊>British journal of ophthalmology >Heritability of intraocular pressure: a classical twin study.
【24h】

Heritability of intraocular pressure: a classical twin study.

机译:眼内压的可遗传性:古典双胞胎研究。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To estimate the heritability of intraocular pressure (IOP) by performing a classical twin study and to determine whether the use of different instruments influences calculation of eye IOP heritability. METHODS: Twin pairs were recruited to participate from the TwinsUK Adult Twin Registry at St. Thomas' Hospital London. IOP was measured using Goldmann applanation tonometry (GAT). A subset of twins also had their IOP measured using the Ocular Response Analyser (ORA; Reichert, Buffalo, NY) and the Dynamic Contour Tonometer (DCT, Pascal; Swiss Microtechnology AG, Port, Switzerland). We compared the covariance of IOP within monozygotic (MZ) and dizygotic (DZ) pairs using genetic modelling techniques to determine the relative contribution of genes and environment to the variation in IOP seen in this population. RESULTS: Data for 422 twin pairs (211 MZ; 211 DZ) were analysed. The mean IOP for GAT was 15.4 (SD 2.7) mm Hg (range: 8.7-26.2 mm Hg). The MZ correlations were significantly higher than DZ for IOP measured by GAT, DCT and ORA (correlation coefficients: GAT: 0.57:0.39, DCT: 0.62:0.36, Goldmann-correlated ORA (IOPg) 0.73:0.47, for MZ:DZ twins, respectively). Modelling suggested heritability for GAT IOP of 0.62, with individual environmental factors accounting for 0.38 of the variation. CONCLUSION: This study demonstrated that genetic effects are important in determining IOP in this twin population. IOP readings differed depending upon the instrument used, and this resulted in different heritability values; genetic factors explained 62%, 63% and 74% of the variation in IOP using GAT, DCT and ORA IOPg, respectively. Environmental factors determined the remainder of the variation.
机译:目的:通过进行经典双语研究来估计眼压(IOP)的可遗传性,并确定不同仪器是否影响眼睛IOP遗传性的计算。方法:招募双对,从伦敦圣托马斯医院的Twinsuk成人双人登记处参加。使用Goldmann Applanation TononoRatry(GAT)测量IOP。双胞胎的子集还使用眼部反应分析仪(ORA; Reichert,Buffalo,NY)和动态轮廓Tonometer(DCT,Pascal;瑞士MicroTechnology AG,瑞士港)测量的IOP。我们使用遗传建模技术与单一(MZ)和Dizygotic(DZ)对中IOP内的IOP的协方差与基因和环境对该人群中所见的IOP变异的相对贡献。结果:分析了422个双对(211Mz; 211dz)的数据。 Gat的平均IOP为15.4(SD 2.7)mm Hg(范围:8.7-26.2mm Hg)。通过GAT,DCT和ORA测量的IOP的MZ相关性显着高于DZ(相关系数:GAT:0.57:0.39,DCT:0.62:0.36,Goldmann相关Ora(IOPG)0.73:0.47,对于MZ:DZ双胞胎,分别)。建模表明GAT IOP的遗传性为0.62,具有各个环境因素的变异0.38。结论:本研究表明,遗传效应对于在该双胞胎群中确定IOP是重要的。 IOP读数根据所使用的仪器而不同,这导致了不同的遗传性值;遗传因素分别使用GAT,DCT和OOPg解释IOP中的62%,63%和74%的变化。环境因素确定了变异的其余部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号