RATIONALE AND OBJECTIVES: A statistical based iterative single-photon emission-computed tomography (SPECT) reconstruction algorithm (OSEM) modeling the depth-dependent collimator response in three dimensions has recently been introduced (OSEM3D). The aim of this study was to evaluate the axial shape fidelity of OSEM3D in comparison to OSEM, not taking this variable into account (OSEM2D). MATERIALS AND METHODS: SPECT and separate spiral CT were performed in a phantom containing spheres filled with In-111. In-111-pentetreotide-SPECT and separate spiral-CT imaging were also performed in 22 patients with neuroendocrine tumors. Using window settings adapting the transversal size of the SPECT hot spots to that on CT and the 50% isocontour as boundary, the three-dimensional extensions (dx, dy, dz) of the SPECT representation of the structures under study were measured. These variables were also determined for CT. Furthermore, an index of eccentricity was calculated by averaging the ratios between dz and dx and dz and dy (IE). For isotropically imaged spheres, IE is 1. RESULTS: For OSEM2D, IE was significantly different from 1 in the phantom data (P < .05); this was not the case for OSEM3D and CT. This finding was accounted for by a significantly greater dz on the OSEM2D-SPECT images. In the patient data, dz was by approximately 15.5% greater for OSEM2D than for the other two modalities (P < .05). CONCLUSIONS: The use of OSEM3D avoids deformation of hot SPECT lesions in z-direction. This may be of particular importance in SPECT/CT hybrid imaging capitalizing on the exact match of both modalities.
机译:理由和目标:最近引入了一种基于统计的迭代单光子发射计算机断层扫描(SPECT)重建算法(OSEM),该算法在三个维度上建模了与深度相关的准直仪​​响应(OSEM3D)。这项研究的目的是评估OSEM3D与OSEM相比的轴向保真度,而不考虑此变量(OSEM2D)。材料与方法:SPECT和单独的螺旋CT在装有幻影的In-111球体中进行。在22例神经内分泌肿瘤患者中,还进行了111-戊戊肽SPECT和单独的螺旋CT成像。使用适合SPECT热点横向尺寸的窗口设置和50%等高轮廓作为边界,测量了所研究结构的SPECT表示的三维延伸(dx,dy,dz)。还为CT确定了这些变量。此外,通过平均dz与dx之间的比率以及dz与dy之间的比率(IE)来计算偏心率指数。对于各向同性成像的球体,IE为1。结果:对于OSEM2D,IE在幻象数据中与1显着不同(P <.05);对于OSEM2D,IE在幻像数据中显着不同于1(P <.05); OSEM3D和CT并非如此。该发现是由于OSEM2D-SPECT图像上的dz显着更大所致。在患者数据中,OSEM2D的dz比其他两种方式的dz高出约15.5%(P <.05)。结论:OSEM3D的使用避免了热SPECT病变在z方向上的变形。利用两种模态的精确匹配,这在SPECT / CT混合成像中可能特别重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号