摘要

The correct use of classical optic long-wave approximation or a complex refraction index for platinum on radiation wavelength 10.6 μm is shown. The factors of absorption efficiency of platinum conductors with the diameters of 3, 10 and 20 μm in dependence on temperature were calculated. It was ascertained that the diameter of a conductor does not influence on normalized temperature dependence of the absorption efficiency factor.
机译:示出了在辐射波长10.6μm上的铂金的经典光学长波近似或复杂折射率的正确使用。 计算铂导体吸收效率的因素,其直径为3,10和20μm,依赖于温度。 确定导体的直径不会影响吸收效率因子的归一化温度依赖性。