首页> 外文期刊>Journal of thermal analysis and calorimetry >Exergy analysis of a domestic refrigerator with brazed plate heat exchanger as condenser
【24h】

Exergy analysis of a domestic refrigerator with brazed plate heat exchanger as condenser

机译:用钎焊板换热器作为冷凝器的国内冰箱的暴力分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Domestic refrigeration system is one of the major energy-consuming devices. Improving its energy and exergy efficiencies plays a vital role in the energy conservation strategies on domestic energy sector. One of the methods to improve the performance is the replacement of existing components and operation of the system in low condensing pressure. Therefore, in this work, the conventional air-cooled condenser has been replaced with water-cooled brazed plate heat exchanger. Besides the COP, exergy efficiency and irreversibility in all the basic components of a 190-L domestic refrigerator have been studied. The experimental results show that the COP and exergy efficiency of the proposed system are 52-68 and 46-55 %, respectively. This is higher than that of the conventional system. Moreover, the irreversibility of the proposed system is 34 % less than that of the conventional system, and the exergy efficiency of HC mixture is 4-7 % higher than R134a under similar operating conditions.
机译:国内制冷系统是主要的耗材设备之一。 提高其能源和漏洞效率在国内能源部门的节能策略中起着至关重要的作用。 提高性能的方法之一是在低冷凝压力下更换现有部件和系统的操作。 因此,在这项工作中,传统的风冷冷凝器已被水冷钎焊板的热交换器代替。 除了COP,在190-L家具冰箱的所有基本组件中,还研究过的官方效率和不可逆转。 实验结果表明,所提出的系统的COP和Outergy效率分别为52-68和46-55%。 这高于传统系统。 此外,所提出的系统的不可逆转性比常规系统的不可逆性为34%,并且在类似的操作条件下,HC混合物的低渗效率高于R134a。