首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >A combined microextraction procedure for isolation of polycyclic aromatic hydrocarbons in ambient fine air particulate matter with determination by gas chromatography-tandem mass spectrometry
【24h】

A combined microextraction procedure for isolation of polycyclic aromatic hydrocarbons in ambient fine air particulate matter with determination by gas chromatography-tandem mass spectrometry

机译:用于在环境细空气颗粒物中分离多环芳烃的组合微萃取方法,通过气相色谱 - 串联质谱法测定

获取原文
获取原文并翻译 | 示例
           

摘要

A novel combined vortex-assisted dispersive liquid-liquid microextraction (VA-DLLME)-micro-solid-phase extraction (mu-SPE) procedure for polycyclic aromatic hydrocarbons (PAHs) in ambient fine particulate matter of aerodynamic diameter of <= 2.5 mu m (PM2.5), was developed. PM2.5 was collected on polytetrafluoroethylene (PTFE)-coated glass fiber filter, that was first processed by ultrasonicating in aqueous solution. Then, VA-DLLME, followed by mu-SPE, were applied to the solution using 1-octanol and graphene oxide as extractant and sorbent, respectively for extracting the PAHs. The PAHs were determined by gas chromatography-tandem mass spectrometry (GC-MS/MS). Parameters affecting the extraction efficiency including selection of the sorbent, duration of DLLME and mu-SPE, desorption solvent type, and ultrasonication-assisted desorption time were investigated. Under the optimum extraction conditions, the method exhibited linear ranges of 0.5-50 mu g/L and 0.5-100 mu g/L depending on the analytes. The limits of detection were in the range of 0.013 mu g/L-0.135 mu g/L. The developed method was applied to determine the PAHs in genuine PM2.5 samples collected on PTFE glass fiber filters. The concentration levels in the atmospheric PM2.5 were determined to be from below the limit of quantification to 0.135 ng/m(3). The relative recoveries obtained from spiked concentrations at 1 mu g/L, and 5 mu g/L were in the range 57-88% with relative standard deviations <14%. (C) 2019 Elsevier B.V. All rights reserved.
机译:一种新的组合涡旋辅助分散液 - 液体微萃取(Va-DILLME) - 微环芳烃(PAH)的环境细颗粒物质的空气动力学直径为<= 2.5亩(PM2.5)开发。在聚四氟乙烯(PTFE)涂覆的玻璃纤维过滤器上收集PM2.5,首先通过超声溶液在水溶液中加工。然后,使用1-辛醇和石墨烯氧化物作为萃取剂和吸附剂,将VA-DLLME施加到溶液中,分别用于提取PAHs。通过气相色谱 - 串联质谱(GC-MS / MS)测定PAHS。研究了影响提取效率的参数,包括吸附剂的选择,DLLME和MU-SPE持续时间,解吸溶剂类型和超声辅助解吸时间。根据最佳提取条件,该方法表现出0.5-50μg/ L和0.5-100μg/ L的线性范围,这取决于分析物。检测限为0.013μg/ L-0.135μg/ L的范围。应用开发方法以确定在PTFE玻璃纤维过滤器上收集的正版PM2.5样品中的PAHS。确定大气PM2.5中的浓度水平从低于定量的限度至0.135ng / m(3)。从尖刺浓度为1μg/ l,5μg/ l获得的相对回收率为57-88%,相对标准偏差<14%。 (c)2019 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号