首页> 外文期刊>Journal of Chemical and Engineering Data: the ACS Journal for Data >Solubility Measurement and Correlation of CO2 in bis(pentafluoroethylsulfonyl)imide ([BETI]) Anion-Based Ionic Liquids: [EMIM][BETI], [BMIM][BETI], [HMIM][BETI]
【24h】

Solubility Measurement and Correlation of CO2 in bis(pentafluoroethylsulfonyl)imide ([BETI]) Anion-Based Ionic Liquids: [EMIM][BETI], [BMIM][BETI], [HMIM][BETI]

机译:二氧化碳(五氟乙基磺基)酰亚胺(β)阴离子离子液体中CO2的溶解度测量和相关性:[emim]β,[Bmim] [beti],[Hmim] [beti]

获取原文
获取原文并翻译 | 示例

摘要

The ionic liquid (IL) + CO2 system was studied for solubility measurement in three distinct [BETI] anion-based ILs: 1-ethyl-3-methylimidazolium bis(pentafluoroethylsulfonyl)imide ([EMIM][BETI]), 1-butyl-3-methylimidazolium bis(pentafluoroethylsulfonyl)imide ([BMIM][BETI]), and 1-hexyl-3-methylimidazolium bis(pentafluoroethylsulfonyl)imide ([HMIM][BETI]) in the experimental ranges of 0.129.3 MPa and 303.2373.2 K. The present study shows the solubility of CO2 in several [BETI] anion-based ILs under specific experimental conditions and compares the effect of three cations: [HMIM], [BMIM], and [EMIM]. CO2 solubility data were measured by determining bubble (or cloud)-point pressures at targeted CO2 mole fractions. It was found that CO2 absorption abilities were placed in the following order: [HMIM][BETI] > [BMIM][BETI] > [EMIM][BETI]. Moreover, these three [BETI]-containing ILs were compared with previously published data for investigating the influence of the [BETI] anion. The result shows that the three [BETI] anion-based ILs have relatively higher solubility for CO2 than any other ILs discussed in this paper. These experimental results also show that the larger amount of the fluoro-alkyl group containing anion increases CO2 solubility. To correlate and calculate the resulting data, the following methods were used: the PR-EoS with one-fluid mixing rule and the modified LydersenJobackReid method. The overall absolute average relative deviation were 0.0172, 0.0246, and 0.0118 for CO2 + [EMIM][BETI], CO2 + [BMIM][BETI], and CO2 + [HMIM][BETI] systems, respectively.
机译:研究了离子液体(IL)+ CO2系统,用于三个不同的β基于阴离子ILS中的溶解度测量:1-乙基-3-甲基咪唑鎓双(五氟乙基磺酰基)酰亚胺([emim] [beti]),1-丁基 - 在实验范围为0.129.3MPa和303.2373的实验范围内,3-甲基-3-甲基磺酰基)和1-己基-3-甲基磺酰基)和1-己基-3-甲基磺酰基)酰亚胺([Hmim]β)和1-己基-3-甲基磺酰基)酰亚胺([Hmim]β)。本研究表明,在特定的实验条件下,CO 2在几种基于β基础ILS中的溶解度,并比较了三个阳离子:[Hmim],[Bmim]和[emim]的效果。通过在靶向CO 2摩尔级分的泡沫(或云) - 点压力测定CO 2溶解度数据。发现将CO 2吸收能力置于以下顺序:[Hmim]β> [Bmim]> [emim] [beti]。此外,将这三种筛选的ILS与先前公布的数据进行了比较,用于研究[beti]阴离子的影响。结果表明,基于三[Beti]阴离子的ILS对二氧化碳的溶解度比本文中讨论的任何其他ILS相对较高。这些实验结果还表明,含有含量的氟代烷基的阴离子的含量增加了CO 2溶解度。为了相关和计算所得到的数据,使用以下方法:具有单流混合规则和改进的Lydersenjackreid方法的PR-EOS。总体绝对平均相对偏差分别为0.0172,0.0246和0.0118用于CO 2 + [emim],CO 2 + [Bmim] [Beti]和CO2 + [Hmim]β系统。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号