首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >Characteristics of surgical prosthetic heart valves and problems around labeling: A document from the European Association for Cardio-Thoracic Surgery (EACTS)-The Society of Thoracic Surgeons (STS)-American Association for Thoracic Surgery (AATS) Valve Labelling Task Force
【24h】

Characteristics of surgical prosthetic heart valves and problems around labeling: A document from the European Association for Cardio-Thoracic Surgery (EACTS)-The Society of Thoracic Surgeons (STS)-American Association for Thoracic Surgery (AATS) Valve Labelling Task Force

机译:外科假肢心脏瓣膜的特征及标签问题:欧洲心动胸外科(EACTS)与欧洲心动外科协会的文献 - 胸外科医生学会(STS) - 胸外科(AATS)瓣膜标签工作组

获取原文
获取原文并翻译 | 示例
           

摘要

Intraoperative surgical prosthetic heart valve (SHV) choice is a key determinant of successful surgery and positive postoperative outcomes. Currently, many controversies exist around the sizing and labeling of SHVs rendering the comparison of different valves difficult. To explore solutions, an expertValve Labelling Task Force was jointly initiated by the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and the American Association for Thoracic Surgery (AATS). The EACTS-STS-AATS Valve Labelling Task Force, comprising cardiac surgeons, cardiologists, engineers, regulators and representatives from the International Organization for Standardization (ISO), and major valve manufacturers, held its first in-person meeting in February 2018 in Paris, France. This article was derived from the meeting's discussions. The Task Force identified the following areas for improvement and clarification: reporting of physical dimensions and characteristics of SHVs determining and labeling of SHV size, in vivo and in vitro testing, and reporting of SHV hemodynamic performance and thrombogenicity. Furthermore, a thorough understanding of the regulatory background and the role of the applicable ISO standards, together with close cooperation between all stakeholders (including regulatory and standard-setting bodies), is necessary to improve the current situation. Cardiac surgeons should be provided with appropriate information to allow for optimal SHV choice. This first article from the EACTS-STS-AATS Valve Labelling Task Force summarizes the background of SHV sizing and labeling and identifies the most important elements where further standardization is necessary.
机译:术中外科假体心脏瓣膜(SHV)选择是成功手术和阳性术后结果的关键决定因素。目前,SHV的尺寸和标记周围存在许多争议,呈现不同阀的比较困难。为了探索解决方案,由欧洲心动胸外科(EACTS),胸外科医生(STS)和美国胸外科协会(AATS协会)共同发起专业人员标签工作队。 eACTS-STS-AATS阀门标签工作队,包括心脏外科医生,心脏病学家,工程师,监管机构以及国际标准化组织(ISO)和主要阀门制造商的代表,于2018年2月在巴黎举行了第一个亲自会议,法国。这篇文章来自会议的讨论。该工作队确定了以下领域以改进和澄清:报告Shvs测定和ShV大小,体内和体外测试标记的特征,报告Shv血液动力学性能和血栓形成性。此外,对监管后背景和适用的ISO标准的作用,以及所有利益攸关方(包括监管和标准制定机构)的密切合作,有必要彻底了解,以改善当前情况。应提供适当信息的心脏外科医生以允许最佳的SHV选择。来自EACTS-STS-AATS阀门标签工作组的第一篇文章总结了SHV尺寸和标签的背景,并确定了进一步标准化的最重要元素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号