Effects of traction on structural properties of degenerated disc using an in vivo rat-tail model.

机译:牵引对退化盘的结构性能的影响使用体内大鼠尾模型。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: An in vivo rat-tail model was adopted to study the structural changes of degenerated intervertebral disc after different traction protocols. OBJECTIVE: To investigate the effects of traction with different modes and magnitudes on disc with simulated degeneration. SUMMARY OF BACKGROUND DATA: Traction has been commonly used in clinical practice for treating low back pain. Its effects on disc with degeneration have not been fully investigated. METHODS: Forty-seven mature rats were used. Continuous static compression of 11 N was applied to the rat caudal 8-9 disc for 2 weeks to simulate disc degeneration. Tractions with different modes (static or intermittent) and magnitudes (1.4 N or 4.2 N) were applied to the degenerated disc for 3 weeks. The disc height was quantified in vivo on days 4, 18, and 39. The treated discs were then harvested for morphologic analysis. RESULTS: Significant decrease in disc height with degenerative morphologic changes was observed after the application of the static compression. The changes in disc height after the application of traction were found to be magnitude dependent. Continuous decrease in disc height was observed after 4.2-N traction, whereas the disc height maintained after traction of 1.4 N. However, no obvious morphologic change was found in comparison with the degenerated discs without traction. CONCLUSION: Although traction was not demonstrated to have restored disc with degeneration, traction with relatively low magnitude was found to have significant beneficial effect in maintaining disc height of degenerated disc, and it might be a potential intervention to slow down the process of degeneration. Future studies of the effects of low-magnitude traction on degenerated disc are recommended.
机译:研究设计:采用体内大鼠尾模型来研究不同牵引方案后退化椎间盘的结构变化。目的:探讨牵引与模拟变性的不同模式和大小的影响。背景数据摘要:牵引常用于治疗低腰疼的临床实践中。它对椎间盘的影响尚未完全调查。方法:使用四十七种成熟大鼠。将11 N的连续静态压缩施用于大鼠尾部8-9个圆盘2周以模拟椎间盘变性。用不同模式(静态或间歇)和幅度(1.4 n或4.2n)施加到退化盘3周内3周。在第4,18和39天内体内测量盘高度。然后收获处理过的盘以进行形态学分析。结果:在静态压缩后观察到椎间盘高度与退行性形态变化的显着降低。发现牵引后的圆盘高度的变化被发现是级别的幅度。在4.2-n牵引后观察到盘高度的连续减少,而牵引后的椎间盘高度保持1.4 n。然而,与无牵引的未退化盘相比,没有发现明显的形态变化。结论:虽然未证明牵引次数以退化恢复椎间盘,但发现具有相对较低的缩小率在维持退化盘的椎间盘高度方面具有显着的有益效果,并且可能是减缓退化过程的潜在干预。建议推荐对低幅度牵引对退化盘的影响的未来研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号