Purpose: To formulate objective functions of a multicriteria fluence map optimization model that correlate well with plan quality metrics, and to solve this multicriteria model by convex approximation. Methods: In this study, objectives of a multicriteria model are formulated to explicitly either minimize or maximize a dose‐at‐volume measure. Given the widespread agreement that dose‐at‐volume levels play important roles in plan quality assessment, these objectives correlate well with plan quality metrics. This is in contrast to the conventional objectives, which are to maximize clinical goal achievement by relating to deviations from given dose‐at‐volume thresholds: while balancing the new objectives means explicitly balancing dose‐at‐volume levels, balancing the conventional objectives effectively means balancing deviations. Constituted by the inherently non‐convex dose‐at‐volume measure, the new objectives are approximated by the convex mean‐tail‐dose measure (CVaR measure), yielding a convex approximation of the multicriteria model. Results: Advantages of using the convex approximation are investigated through juxtaposition with the conventional objectives in a computational study of two patient cases. Clinical goals of each case respectively point out three ROI dose‐at‐volume measures to be considered for plan quality assessment. This is translated in the convex approximation into minimizing three mean‐tail‐dose measures. Evaluations of the three ROI dose‐at‐volume measures on Pareto optimal plans are used to represent plan quality of the Pareto sets. Besides providing increased accuracy in terms of feasibility of solutions, the convex approximation generates Pareto sets with overall improved plan quality. In one case, the Pareto set generated by the convex approximation entirely dominates that generated with the conventional objectives. Conclusion: The initial computational study indicates that the convex approximation outperforms the conventional objectives in aspects of accuracy and plan quality.
机译:目的:制定多轨道注释的客观函数,这些函数与计划质量指标相关,并通过凸近似来解决该多轨道模型。方法:在本研究中,配制多标准模型的目的以明确地最小化或最大化剂量的量度。鉴于剂量 - 体积水平在计划质量评估中发挥重要作用的广泛协议,这些目标与计划质量指标相相关。这与传统目标相反,传统目标是通过与给定剂量阈值的偏差最大化临床目标成果:在平衡新目标意味着明确地平衡剂量级别,有效地平衡传统的目标平衡偏差。由固有的非凸剂量测量构成,新目的被凸均值尾剂量测量(CVAR测量)近似,产生多标准模型的凸起近似。结果:通过对两个患者案例的计算研究中的常规目标来研究使用凸近似的优点。每种案例的临床目标分别指出三个投资回报剂量措施,以考虑计划质量评估。这在凸起的近似值中转化为最小化三种平均尾剂量措施。对Pareto最佳计划的三种ROI剂量措施的评估用于表示Pareto集的计划质量。除了在解决方案的可行性方面提供提高的准确性外,凸近似还产生了整体改善的计划质量的帕累托集。在一种情况下,由凸近似生成的帕累托集完全占据传统目标产生的主导。结论:初始计算研究表明,凸近似优于准确性和规模方面的传统目标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号