首页> 外文期刊>Environmental Science and Pollution Research >Simultaneous detection of perchlorate and bromate using rapid high-performance ion exchange chromatography-tandem mass spectrometry and perchlorate removal in drinking water
【24h】

Simultaneous detection of perchlorate and bromate using rapid high-performance ion exchange chromatography-tandem mass spectrometry and perchlorate removal in drinking water

机译:快速高性能离子交换色谱 - 串联质谱法同时检测高氯酸盐和溴酸盐,饮用水中的高氯酸盐去除

获取原文
获取原文并翻译 | 示例
       

摘要

Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 mu g/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.
机译:饮用水中的高氯酸盐和溴酸盐发生引起的健康问题,因为它们对甲状腺功能和致癌性的影响。本研究的目的是三倍:(1)推进同时快速检测饮水系统中高氯酸盐和溴酸盐的敏感方法,(2)系统地研究这两种污染物在密苏里州饮用水处理系统中的发生,( 3)检查有效的吸附剂,以使高氯酸盐在饮用水中。快速的高性能离子交换色谱 - 串联质谱(HPIC-MS / MS)方法进行了前进,用于同时检测饮用水中的高氯酸盐和溴酸盐。 HPIC-MS / MS方法快速,不需要水样品的预浓度,并且分别具有0.04和0.01μg/ L的高氯酸盐和溴酸盐的检测限。应用该方法以在不同季节期间共测量共氯酸盐和溴酸盐浓度23种选定的密苏里饮用水处理系统。选择的水系统包括不同的源水域:地下水,湖水,河水和地下水受地表水的影响。在监测的大多数饮用水样本中,高氯酸盐和溴酸盐的浓度低于或接近方法检测限。研究了各种吸附剂的高氯酸盐去除。阳离子有机粘土(TC-99)表现出从饮用水基质中有效地除去高氯酸盐。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号