...
首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Effects of column back pressure on supercritical fluid chromatography separations of enantiomers using binary mobile phases on 10 chiral stat ionary phases
【24h】

Effects of column back pressure on supercritical fluid chromatography separations of enantiomers using binary mobile phases on 10 chiral stat ionary phases

机译:柱背压对使用10种手性Stat离子相的二元流动相进行超临界流体色谱分离对映体的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The most obvious difference of packed column supercritical fluid chromatography (pSFC) from HPLC is the use of CO_2 with an elevated column back pressure. However, how back pressure affects SFC separations using methanol/CO_2 binary mobile phase has neither been thoroughly studied experimentally, nor well understood in theory. We studied the effects of back pressure for the most widely applied SFC enantiomeric separation. The impacts of back pressure on dead time (t_0), solute retention (k), selectivity (α), efficiency (N) and resolution (Rs) were studied on 10 chiral columns using 11 pairs of drug-like enantiomers covering the common retention time range using the mobile phase of 20/80 methanol/CO_2. Increased apparent t_0 was observed at an increased column back pressure. Careful analysis of the experimental data indicated that t_0 depends not only on the relative density change along the column length, but also on the adsorption of modifier (methanol) onto the stationary phase. The measured k over pressure was found to follow a linear relationship. Moreover, a linear correlation was derived between the k and the rate of retention change with pressure, dk/dP. The resulting empirical equation not only is universally applicable for all 10 tested columns, but also successfully explains the constant selectivity observed with column back pressure changing from 100 to 200bar under the mobile phase condition. The observed slight efficiency loss due to pressure increase was found to be statistically significant. The combined effects of pressure from all the SFC attributes (t_0, k, α and N) on resolution were confirmed by the experimental results from 48 enantiomeric resolutions. As the column back pressure increased from 100 to 200bar, resolution decreased only slightly, on average 6%, due mainly to the retention and efficiency decrease. The importance and possible application of our study results will also be discussed.
机译:HPLC填充柱超临界流体色谱(pSFC)最明显的区别是使用了具有升高的柱背压的CO_2。但是,背压如何影响使用甲醇/ CO_2二元流动相进行SFC分离的方法尚未在实验上进行深入研究,也没有在理论上得到充分理解。我们研究了背压对最广泛应用的SFC对映体分离的影响。使用11对涵盖共同保留时间的类药物对映体,在10个手性色谱柱上研究了背压对死时间(t_0),溶质保留(k),选择性(α),效率(N)和分离度(Rs)的影响时间范围是使用20/80甲醇/ CO_2的流动相。在增加的柱背压下观察到的表观t_0增加。仔细分析实验数据表明,t_0不仅取决于沿色谱柱长度的相对密度变化,还取决于改性剂(甲醇)在固定相上的吸附。发现测得的在压力下的k遵循线性关系。此外,得出了k与保留力随压力的变化率dk / dP之间的线性关系。所得的经验方程式不仅可普遍用于所有10个测试色谱柱,而且还可以成功地说明在流动相条件下,色谱柱背压从100 bar变为200 bar时观察到的恒定选择性。发现由于压力增加而导致的观察到的轻微效率损失在统计学上是显着的。来自48个对映体分辨率的实验结果证实了来自所有SFC属性(t_0,k,α和N)的压力对分辨率的综合影响。当色谱柱背压从100bar增加到200bar时,分离度仅略微降低,平均降低6%,这主要是由于保留时间和效率下降所致。我们的研究结果的重要性和可能的​​应用也将被讨论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号