首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Validation of adsorbents for sample preconcentration in compound-specific isotope analysis of common vapor intrusion pollutants
【24h】

Validation of adsorbents for sample preconcentration in compound-specific isotope analysis of common vapor intrusion pollutants

机译:在常见蒸气侵入污染物的化合物特定同位素分析中验证用于样品预富集的吸附剂

获取原文
获取原文并翻译 | 示例
           

摘要

Isotope ratios of volatile organic compounds (VOCs) in the environment are often of interest in contaminant fate studies. Adsorbent preconcentration-thermal desorption of VOCs can be used to collect environmental vapor samples for compound-specific isotope analysis (CSIA). While active adsorbent samplers offer logistic benefits in handling large volumes of air, their performance in preserving VOCs isotope ratios was not previously tested under sampling conditions corresponding to typical indoor air sampling conditions. In this study, the performance of selected adsorbents was tested for preconcentration of TCE (for determination of C and Cl isotope ratios), PCE (C and Cl) and benzene (C and H). The key objective of the study was to identify the adsorbent(s) permitting preconcentration of the target VOCs present in air at low μg/m~3 concentrations, without significant alteration of their isotope ratios. Carboxen 1016 was found to perform well for the full range of tested parameters. Carboxen 1016 can be recommended for sampling of TCE, PCE and benzene, for CSIA, from air volumes up to 100L. Variable extent of isotope ratio alteration was observed in the preconcentration of the target VOCs on Carbopack B and Carbopack X, resulting from partial analyte loss via adsorbent bed breakthrough and (possibly) via incomplete desorption. The results from testing the Carbopack B and Carbopack X highlight the need of adsorbent performance validation at conditions fully representative of actual sample collection conditions, and caution against extrapolation of performance data toward more challenging sampling conditions.
机译:环境中挥发性有机化合物(VOC)的同位素比率通常是污染物归宿研究中关注的问题。 VOCs的吸附剂预浓缩-热解吸可用于收集环境蒸汽样品,以进行化合物特定的同位素分析(CSIA)。尽管活性吸附剂采样器在处理大量空气方面具有逻辑上的好处,但先前未在与典型室内空气采样条件相对应的采样条件下测试其保持VOC同位素比的性能。在这项研究中,针对TCE(用于确定C和Cl同位素比),PCE(C和Cl)和苯(C和H)的预浓缩测试了所选吸附剂的性能。该研究的主要目的是确定一种吸附剂,该吸附剂可以预浓缩空气中低μg/ m〜3浓度的目标VOC,而不会显着改变其同位素比。发现Carboxen 1016在所有测试参数范围内均表现良好。推荐使用Carboxen 1016对CSIA进行TCE,PCE和苯的采样,空气量不超过100L。在Carbopack B和Carbopack X上,目标VOC的预浓缩中观察到了不同程度的同位素比率变化,这是由于吸附床穿透和(可能)不完全解吸造成部分分析物损失的结果。对Carbopack B和Carbopack X的测试结果突出表明,必须在完全代表实际样品采集条件的条件下验证吸附剂性能,并注意不要将性能数据外推至更具挑战性的采样条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号