摘要

A novel analytical toxicology method has been developed for the analysis of drugs of abuse in human urine by using a high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS). This method allows for the detection of different drugs of abuse, including amphetamines, cocaine, opiate alkaloids, cannabinoids, hallucinogens and their metabolites. After solid-phase extraction with Oasis HLB cartridges, spiked urine samples were analysed by HPLC/LTQ-Orbitrap-MS using an electrospray interface in positive ionisation mode, with resolving power of 30,000 full width at half maximum (FWHM). Gradient elution off of a Hypersil Gold PFP column (50mm×2.1mm) allowed to resolve 65 target compounds and 3 internal standards in a total chromatographic run time of 20min. Validation of this method consisted of confirmation of identity, selectivity, linearity, limit of detection (LOD), lowest limits of quantification (LLOQ), accuracy, precision, extraction recovery and matrix effect. The regression coefficients (r~2) for the calibration curves (LLOQ - 100ng/mL) in the study were ≥0.99. The LODs for 65 validated compounds were better than 5ng/ml except for 4 compounds. The relative standard deviation (RSD), which was used to estimate repeatability at three concentrations, was always less than 15%. The recovery of extraction and matrix effects were above 50 and 70%, respectively. Mass accuracy was always better than 2ppm, corresponding to a maximum mass error of 0.8 millimass units (mmu). The accurate masses of characteristic fragments were obtained by collisional experiments for a more reliable identification of the analytes. Automated data analysis and reporting were performed using ToxID software with an exact mass database. This procedure was then successfully applied to analyse drugs of abuse in a real urine sample from subject who was assumed to be drug addict.
机译:通过使用高分辨率和高质量高精度混合线性离子阱-Orbitrap质谱仪(LTQ-Orbitrap-MS),开发了一种新颖的分析毒理学方法,用于分析人尿中的滥用药物。这种方法可以检测到各种滥用药物,包括苯丙胺,可卡因,鸦片生物碱,大麻素,致幻剂及其代谢产物。在使用Oasis HLB柱进行固相萃取后,使用正电离模式下的电喷雾接口通过HPLC / LTQ-Orbitrap-MS分析加标的尿液样品,分辨力为30,000全宽(一半最大)(FWHM)。从Hypersil Gold PFP色谱柱(50mm×2.1mm)上洗脱下来,可在20分钟的总色谱运行时间内分离出65种目标化合物和3种内标。该方法的验证包括确认同一性,选择性,线性,检测限(LOD),最低定量限(LLOQ),准确性,精密度,提取回收率和基质效应。研究中校正曲线(LLOQ-100ng / mL)的回归系数(r〜2)≥0.99。除4种化合物外,对65种经验证化合物的LOD均优于5ng / ml。用于估计三种浓度下的重复性的相对标准偏差(RSD)始终小于15%。提取率和基质效应的回收率分别高于50%和70%。质量精度始终优于2ppm,对应的最大质量误差为0.8毫玛单位(mmu)。通过碰撞实验可获得准确质量的特征片段,以更可靠地鉴定分析物。使用具有精确质量数据库的ToxID软件执行自动数据分析和报告。然后,该程序成功地应用于分析来自假定为吸毒成瘾者的真实尿液样本中的滥用药物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号