首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Comparison of several sorbents for continuous in situ derivatization and preconcentration of low-molecular mass aldehydes prior to liquid chromatography-tandem mass spectrometric determination in water samples
【24h】

Comparison of several sorbents for continuous in situ derivatization and preconcentration of low-molecular mass aldehydes prior to liquid chromatography-tandem mass spectrometric determination in water samples

机译:液相色谱-串联质谱测定水中低分子量醛类物质连续原位衍生和预浓缩前几种吸附剂的比较

获取原文
获取原文并翻译 | 示例

摘要

A comparative study of six SPE conventional and non-conventional sorbent materials (silica RP-C-18, LiChrolut EN, Amberlite XAD-2, C-60 fullerene, multiwall carbon nanotubes and graphitized carbon black) was carried out for the in situ derivatization/preconcentration of eight aldehydes with 2,4-dinitrophenylhydrazine. Although two of the sorbents, LiChrolut EN and RP-C18, turned out to be the most suitable for ultratrace analysis of the aldehydes, LiChrolut EN showed higher capacity for 2,4-dinitrophenylhydrazine trapping (higher efficiency for the in situ derivatization reaction) and superior performance in terms of sensitivity (likely a result of its increased sample breakthrough volume). The LiChrolut EN-based method combined with LC-MS/MS allowed the determination of aldehydes over the linear range of 0.02-15 mu g l(-1), with limits of detection at 6-24 ng l(-1) and precision of 3.2-7.2%. The method was applied to determine low-molecular mass aldehydes in water samples. These results indicate that the method proposed is a straightforward and sensitive tool for the determination of these aldehydes in water samples providing better results than those LC-MS/MS reported alternatives in terms of the limit of detection, sample requirements for analysis and cost.
机译:对六种SPE常规和非常规吸附剂材料(二氧化硅RP-C-18,LiChrolut EN,Amberlite XAD-2,C-60富勒烯,多壁碳纳米管和石墨化炭黑)进行了原位衍生化的比较研究。用2,4-二硝基苯基肼对八种醛进行预浓缩。尽管事实证明,两种吸附剂LiChrolut EN和RP-C18最适合于醛的超痕量分析,但LiChrolut EN表现出更高的2,4-二硝基苯肼捕集能力(原位衍生反应效率更高)和在灵敏度方面表现出卓越的性能(可能是由于样品突破体积增加所致)。基于LiChrolut EN的方法与LC-MS / MS结合使用,可以在0.02-15 mu gl(-1)的线性范围内测定醛类,检测限为6-24 ng l(-1),精密度为3.2-7.2%。该方法用于测定水样中的低分子量醛类。这些结果表明,所提出的方法是一种简单而灵敏的测定水中样品中醛的工具,在检测限度,样品分析要求和成本方面,提供了比LC-MS / MS报告的替代方法更好的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号