...
首页> 外文期刊>Journal of Applied Polymer Science >Modification and characterization of poly (ethylene terephthalate)-grafted- acrylic acid/acryl amide fiber for removal of lead from human plasma and environmental samples
【24h】

Modification and characterization of poly (ethylene terephthalate)-grafted- acrylic acid/acryl amide fiber for removal of lead from human plasma and environmental samples

机译:聚对苯二甲酸乙二酯接枝丙烯酸/丙烯酰胺纤维的改性和表征,用于从人血浆和环境样品中去除铅

获取原文
获取原文并翻译 | 示例

摘要

A new fibrous adsorbent was prepared by grafting acrylic acid/acryl amide (AA/AAm) comonomers onto poly (ethylene terephthalate) (PET) fibers. The resulting sorbent has been characterized by Fourier transform infrared (FT-IR), elemental analysis, thermogravimetric analysis (TGA), FT-Raman, and scanning electron microscopy (SEM) and studied for the preconcentration and determination of trace Pb (II) ion from human biological fluid and environmental water samples. The optimum pH value for sorption of the metal ion was 8. The sorption capacity of functionalized resin is 44.1 mg g ~(-1). The chelating sorbent can be reused for 20 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 100.2% was obtained for the metal ion with 0.5M nitric acid as eluting agent. Effect of grafting yield, shaking time, shape of sorbent, and pH of the medium on adsorption of the metal ion were investigated. Scatchard analysis revealed that the homogeneous binding sites were formed in the polymers. The equilibrium adsorption data of Pb (II) on modified fiber were analyzed by Langmuir, Freundlich, Temkin, and Redlich-Peterson models. Based on equilibrium adsorption data, the Langmuir, Freundlich, and Temkin constants were determined as 0.236, 10.544, and 9.497 at pH 8 and 20°C, respectively. The method was applied for lead ions determination from human plasma and sea water sample.
机译:通过将丙烯酸/丙烯酰胺(AA / AAm)共聚单体接枝到聚对苯二甲酸乙二酯(PET)纤维上,制备了一种新的纤维状吸附剂。所得吸附剂已通过傅里叶变换红外(FT-IR),元素分析,热重分析(TGA),傅立叶变换拉曼光谱和扫描电子显微镜(SEM)进行了表征,并进行了痕量铅(II)离子的预富集和测定的研究。从人类生物流体和环境水样本中提取。吸附金属离子的最佳pH值为8。功能化树脂的吸附容量为44.1 mg g〜(-1)。螯合吸附剂可重复使用20个吸附-解吸循环,而吸附能力没有任何显着变化。用0.5M硝酸作为洗脱剂,金属离子的回收率为100.2%。研究了接枝率,振荡时间,吸附剂的形状和介质的pH值对金属离子吸附的影响。斯卡查德分析表明在聚合物中形成了均质的结合位点。用Langmuir,Freundlich,Temkin和Redlich-Peterson模型分析了改性纤维上Pb(II)的平衡吸附数据。根据平衡吸附数据,在pH 8和20°C下,Langmuir,Freundlich和Temkin常数分别确定为0.236、10.544和9.497。该方法用于人体血浆和海水样品中铅离子的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号