The electrical aging of polyurethane under ac voltage has been investigated using Weibull statistical analysis. It is shown that the time to breakdown characteristic (V-t) of this polymer includes three zones corresponding, respectively, to the youth defects, the statistical dispersion of the intrinsic defects, and the real aging of the polymer. The variation of slope of the V-t curve is related to the change of the degradation mechanism. This degradation is governed by the action of partial discharges according to three stages: (1) the appearance of very fast discharges within the cavities; (2) the initiation of discharges resulting of a very thin layer of oxidation products; and (3) the formation of crystals having small dimensions leading to degradation by electrical tree. (C) 2008 Wiley Periodicals, Inc.
机译:使用Weibull统计分析研究了交流电压下聚氨酯的电老化。结果表明,该聚合物的击穿时间(V-t)包括三个区域,分别对应于青春缺陷,固有缺陷的统计分散和聚合物的实际老化。 V-t曲线的斜率变化与降解机理的变化有关。这种降解受局部放电作用的控制,可分为三个阶段:(1)腔内出现非常快速的放电; (2)由于很薄的氧化产物层而引起的放电; (3)小尺寸晶体的形成导致电树的降解。 (C)2008 Wiley期刊公司