首页> 外文期刊>Journal of Applied Polymer Science >H-1 T-2-NMR monitoring of crosslinked polyolefin aging
【24h】

H-1 T-2-NMR monitoring of crosslinked polyolefin aging

机译:H-1 T-2-NMR监测交联聚烯烃的老化

获取原文
获取原文并翻译 | 示例

摘要

This work examines the correlation between the H-1-NMR T-2 relaxation constant and the mechanical properties of aged crosslinked polyolefin cable insulation. T-2 experiments on unswollen samples could not differentiate between unaged and highly aged materials; all exhibited H-1 T-2 constants of approximately 0.5 ms. To accentuate the effects of aging, samples were swollen in various solvents. Unaged samples had T-2 values of approximately 15 ms in good solvents. With thermal aging, T-2 values decreased as the ultimate tensile elongation decreased. However, the correlation between T-2 and elongation differed for samples irradiated with high-energy radiation and for materials aged above versus below the crystalline melting temperature. (C) 2003 Wiley Periodicals, Inc. [References: 15]
机译:这项工作研究了H-1-NMR T-2弛豫常数与老化的交联聚烯烃电缆绝缘层的机械性能之间的关系。未溶胀样品的T-2实验无法区分未老化和高度老化的材料。全部显示约0.5毫秒的H-1 T-2常数。为了强调老化的影响,将样品在各种溶剂中溶胀。未老化样品在良好溶剂中的T-2值约为15 ms。随着热老化,T-2值随着极限拉伸伸长率的降低而降低。然而,T-2与伸长率之间的相关性对于高能射线辐照的样品以及相对于高于或低于晶体熔融温度老化的材料而言是不同的。 (C)2003 Wiley Periodicals,Inc. [参考:15]