首页> 外文期刊>Journal of Agricultural and Food Chemistry >Effects of Thermal Processing on the Enzyme-Linked Immunosorbent Assay (ELISA) Detection of Milk Residues in a Model Food Matrix
【24h】

Effects of Thermal Processing on the Enzyme-Linked Immunosorbent Assay (ELISA) Detection of Milk Residues in a Model Food Matrix

机译:热处理对模型食品基质中牛奶残留的酶联免疫吸附测定(ELISA)检测的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Food products and ingredients are frequently tested for the presence of undeclared allergenic food residues (including milk) using commercial enzyme-linked immunosorbent assays (ELISAs). However, little is understood about the efficacy of these kits with thermally processed foods. This study evaluated the performance of three milk ELISA kits with a model food processed by several methods. A model food (pastry dough squares) was spiked with nonfat dry milk at several concentrations. The pastry squares were processed by boiling (100 °C for 2 min), baking (190 °C for 30 min), frying (190 °C for 2 min), and retorting (121 °C for 20 min with 17 psi overpressure). Samples were analyzed with three commercial ELISA kits: Neogen Veratox Total Milk, ELISA Systems β-lactoglobulin, and ELISA Systems casein. The detection of milk residues depended upon the type of processing applied to the food and the specific milk analyte targeted by the ELISA kit. Poor recoveries were obtained in all processed samples (2-10% of expected values) using the β-lactoglobulin kit. Better recoveries were obtained in boiled samples (44 and 59%, respectively) using the total milk and casein kits. However, these kits performed poorly with baked (9 and 21%) and fried (7 and 18%) samples. Moderate recoveries were observed in retorted samples (23 and 28%). The decreased detection in processed samples is likely due to protein modifications, including aggregation and Maillard reactions, which affect the solubility and immunoreactivity of the antigens detected by the ELISA methods. The observed decreases in ELISA detection of milk are dramatic enough to affect risk-assessment decisions. However, a lower detection of milk residues does not necessarily indicate decreased allergenicity. These ELISA kits are not acceptable for all applications, and users should understand the strengths and limitations of each method.
机译:经常使用商业酶联免疫吸附测定(ELISA)对食品和成分进行测试,以检查是否存在未声明的致敏食品残留(包括牛奶)。然而,对于这些试剂盒与热加工食品的功效了解甚少。这项研究评估了三种牛奶ELISA试剂盒与通过几种方法加工的模型食品的性能。在模型食物(糕点面团正方形)上添加脱脂奶粉,并添加几种浓度。通过煮沸(100°C 2分钟),烘烤(190°C 30分钟),油炸(190°C 2分钟)和蒸煮(121°C 20分钟,压力为17 psi超压)来处理糕点方块。 。使用三种市售ELISA试剂盒分析样品:Neogen Veratox全脂牛奶,ELISA系统β-乳球蛋白和ELISA系统酪蛋白。牛奶残留物的检测取决于应用于食品的加工类型以及ELISA试剂盒靶向的特定牛奶分析物。使用β-乳球蛋白试剂盒在所有处理过的样品中回收率均较差(预期值的2-10%)。使用全脂牛奶和酪蛋白试剂盒,在煮沸的样品中回收率更高(分别为44%和59%)。但是,这些套件在烘焙(分别为9%和21%)和油炸(分别为7%和18%)样品时效果较差。在干馏样品中观察到中等回收率(23%和28%)。处理过的样品中检出率降低可能是由于蛋白质修饰,包括聚集和美拉德反应,它们会影响ELISA方法检测到的抗原的溶解度和免疫反应性。牛奶中ELISA检测的观察到的下降足以影响风险评估决策。但是,较低的牛奶残留检测并不一定表明变应原性降低。这些ELISA试剂盒不适用于所有应用,用户应了解每种方法的优点和局限性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号