A novel method has been developed to measure the apparent thermal conductivity of thin coatings based on measuring the heat flux through the coatings aswell as the external heat transfer coefficient of an uncoated sample using a modified slug calorimeter configuration. The method was tested on cold gas dynamically sprayed alumina-reinforced aluminum coatings deposited on Al 7075 alloy substrates, and verified by a standard steady-state method. The very low apparent thermal conductivities measured between ?150 °C and +200 °C have been attributed to the presence of numerous splat boundaries, pores and microcracks the width of which changes in response to temperature gradients and hence differential thermal expansion coefficients.
机译:已开发出一种新方法来测量薄涂层的表观导热系数,该方法基于使用改良的塞量热仪配置测量通过涂层的热通量以及未涂层样品的外部传热系数。该方法在沉积在Al 7075合金基材上的冷气动态喷涂氧化铝增强铝涂层上进行了测试,并通过标准稳态方法进行了验证。在?150°C和+200°C之间测得的非常低的表观热导率是由于存在许多裂纹边界,孔和微裂纹,其宽度随温度梯度变化而变化的,因此其热膨胀系数也不同。