首页> 外文期刊>The Journal of Urology >Ocular radiation exposure in modern urological practice
【24h】

Ocular radiation exposure in modern urological practice

机译:现代泌尿外科实践中的眼部辐射暴露

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: The human eye is a highly radiosensitive portion of the body and repeat radiation exposure can lead to cataract. The minimum fractionated long-term dose to initiate cataract formation is about 2,500 mSv. We determined whether further radiation related precautions are necessary to protect the eyes of the surgeon. Materials and Methods: Radiation doses received near the right eye of the operating surgeon were measured with a thermoluminescent dosimeter badge worn near the eye of 6 urologists for a single endourological procedure at an academic center. Procedures included stent insertion, ureteroscopic lithotripsy and percutaneous nephrolithotomy. The mean radiation dose was calculated. Extrapolated doses required to potentiate cataract formation were also calculated. Results: We assessed 28 urological procedures for radiation exposure, of which 13 were ureteroscopy done for calculus disease (range 0.05 to 0.66 mSv) and 7 were ureteral stent insertion (range 0.13 to 0.32 mSv). The mean radiation dose received during these cases was 0.208 mSv. Based on the mean dose and an average of 20 such cases per month, it would take about 50 years to reach the minimum threshold for progressive cataract formation. Eight percutaneous renal operations were performed and the mean dose received was 0.125 mSv (range 0.04 to 0.22). Based on 10 cases per month, this would require more than 160 years of exposure to reach the minimal threshold. Conclusions: Long-term radiation can lead to cataract formation. However, the accumulated lifetime exposure of the typical urologist may not necessitate further safety precautions, such as lead-lined glasses.
机译:目的:人眼是人体对放射线高度敏感的部分,反复暴露于辐射会导致白内障。启动白内障形成的最小分次长期剂量约为2500 mSv。我们确定了是否需要采取进一步的辐射相关预防措施来保护外科医生的眼睛。材料和方法:在学术中心通过一次泌尿科手术,在6名泌尿科医师的眼睛附近戴上热辐射剂量计徽章,测量手术外科医生右眼附近的辐射剂量。程序包括支架插入,输尿管镜碎石术和经皮肾镜取石术。计算平均辐射剂量。还计算了增强白内障形成所需的外推剂量。结果:我们评估了28例泌尿外科放射线照射程序,其中有13例针对结石疾病进行了输尿管镜检查(范围为0.05至0.66 mSv),有7例为输尿管支架置入术(范围为0.13至0.32 mSv)。在这些情况下,平均辐射剂量为0.208 mSv。根据平均剂量和每月平均20例此类病例,大约需要50年才能达到进行性白内障形成的最低阈值。进行了八次经皮肾手术,平均接受剂量为0.125 mSv(范围为0.04至0.22)。基于每月10例,这将需要超过160年的暴露时间才能达到最低阈值。结论:长期辐射可导致白内障形成。但是,典型的泌尿科医生的终生累积暴露量可能并不需要进一步的安全预防措施,例如衬铅玻璃。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号