Chloride-induced corrosion rate (i(corr)) prediction models for RC structures in the marine tidal zone that incorporate the influence of crack width (w(cr)), cover (c) and concrete quality are proposed. Parallel corrosion experiments were carried out for 2 1/4 years by exposing one half of 210 beam specimens (120 x 130 x 375 mm long) to accelerated laboratory corrosion (cyclic wetting and drying) while the other half underwent natural corrosion in the tidal zone. Experimental variables were w(cr) (0, incipient crack, 0.4, 0.7 mm), c (20,40 mm), binder type (PC, PC/GGBS, PC/FA) and w/b ratio (0.40, 0.55). The two proposed models (one each for accelerated and natural i(corr)) can aid not only in quantifying the propagation phase, but also provide a novel way to select c, w(cr) and concrete quality. (C) 2015 Elsevier Ltd. All rights reserved.
机译:提出了结合潮汐宽度(w(cr)),覆盖层(c)和混凝土质量的影响的潮汐带钢筋混凝土结构的氯化物腐蚀速率(i(corr))预测模型。平行腐蚀实验进行了2 1/4年,方法是将210个射线试样的一半(120 x 130 x 375毫米长)暴露于加速的实验室腐蚀(循环润湿和干燥),而另一半则在潮汐带进行自然腐蚀。 。实验变量为w(cr)(0,初期裂纹,0.4,0.7 mm),c(20,40 mm),粘合剂类型(PC,PC / GGBS,PC / FA)和w / b比(0.40,0.55) 。提出的两个模型(分别用于加速和自然i(corr))不仅可以帮助量化传播阶段,而且还提供了一种选择c,w(cr)和混凝土质量的新颖方法。 (C)2015 Elsevier Ltd.保留所有权利。