首页> 外文期刊>Investigative ophthalmology & visual science >Flicker-induced retinal arteriole dilation is reduced by ambient lighting
【24h】

Flicker-induced retinal arteriole dilation is reduced by ambient lighting

机译:通过环境照明减少闪烁引起的视网膜小动脉扩张

获取原文
获取原文并翻译 | 示例
           

摘要

METHODS. Twenty healthy nonsmokers participated in a balanced 2 × 2 crossover study. Retinal vascular imaging was performed with the dynamic vessel analyzer under reduced or normal ambient lighting, then again after 20 minutes under the alternate condition. Baseline calibers of selected arteriole and venule segments were recorded in measurement units. Maximum percentage dilations from baseline during 20 seconds of luminance flicker were calculated from the mean of three measurement cycles. Within-subject differences were assessed by repeated measures analysis of variance with the assumption of no carryover effects and pairwise comparisons from the fitted model.PURPOSE. To investigate the impact of ambient room lighting on the magnitude of flicker light– induced retinal vasodilations in healthy individuals.RESULTS. Mean (SD) maximum arteriole dilations during flicker stimulation under reduced and normal ambient lighting were 4.8% (2.3%) and 4.1% (1.9%), respectively (P = 0.019). Maximum arteriole dilations were (mean ± 95% confidence interval) 0.7% ± 0.6% lower under normal ambient lighting compared with reduced lighting. Ambient lighting had no significant effect on maximum venular dilations during flicker stimulation or on the baseline calibers of arterioles or venules.CONCLUSIONS. Retinal arteriole dilation in response to luminance flicker stimulation is reduced under higher ambient lighting conditions. Reduced responses with higher ambient lighting may reflect reduced contrast between the ON and OFF flicker phases. Although it may not always be feasible to conduct studies under reduced lighting conditions, ambient lighting levels should be consistent to ensure that comparisons are valid.
机译:方法。 20名健康的非吸烟者参加了平衡的2×2交叉研究。用动态血管分析仪在减少或正常的环境光下进行视网膜血管成像,然后在备用条件下20分钟后再次进行。所选小动脉和小静脉段的基线口径以测量单位记录。根据三个测量周期的平均值,计算出在20秒的亮度闪烁期间自基线的最大膨胀百分比。通过重复测量方差分析来评估受试者内部差异,并假设没有残留影响,并通过拟合模型进行成对比较。研究室内照明对闪烁波引起的健康个体视网膜血管舒张程度的影响。结果。在减少和正常环境照明下的闪烁刺激期间,平均(SD)最大小动脉扩张分别为4.8%(2.3%)和4.1%(1.9%)(P = 0.019)。与减少的照明相比,在正常的环境照明下,最大的小动脉扩张度(平均±95%置信区间)降低了0.7%±0.6%。结论闪烁刺激过程中,环境照明对最大静脉扩张或小动脉或小静脉的基线口径均无明显影响。在较高的环境照明条件下,响应于亮度闪烁刺激的视网膜小动脉扩张减少。在较高环境照明下的响应降低可能反映了ON和OFF闪烁相位之间的对比度降低。尽管在减少的照明条件下进行研究可能并不总是可行的,但环境照明水平应保持一致以确保比较有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号