The paper reports on investigation of the pH sensing mechanism of thick film RuO2-Ta2O5 sensors by using X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). Interdigitated conductimetric pH sensors were screen printed on alumina substrates. The microstructure and elemental composition of the films were examined by scanning electron microscopy and energy dispersive spectroscopy. The XPS studies revealed the presence of Ru ions at different oxidation states and the surface hydroxylation of the sensing layer increasing with increasing pH. The EIS analysis carried out in the frequency range 10 Hz-2 MHz showed that the electrical parameters of the sensitive electrodes in the low frequency range were distinctly dependent on pH. The charge transfer and ionic exchange occurring at metal oxide-solution interface were indicated as processes responsible for the sensing mechanism of thick film RuO2-Ta2O5 pH sensors. (C) 2016 Elsevier B.V. All rights reserved.
机译:本文利用X射线光电子能谱(XPS)和电化学阻抗谱(EIS)研究了厚膜RuO2-Ta2O5传感器的pH传感机理。叉指式电导pH传感器丝网印刷在氧化铝基板上。膜的显微结构和元素组成通过扫描电子显微镜和能量色散光谱法检查。 XPS研究揭示了Ru离子在不同氧化态下的存在,并且传感层的表面羟基化随着pH值的增加而增加。在10 Hz-2 MHz频率范围内进行的EIS分析表明,在低频范围内,敏感电极的电参数明显取决于pH值。指示在金属氧化物-溶液界面发生的电荷转移和离子交换是负责厚膜RuO2-Ta2O5 pH传感器传感机制的过程。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号