首页> 外文期刊>Analytica chimica acta >Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls
【24h】

Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls

机译:三重四极杆串联质谱:高分辨率磁部门仪器的真正替代品,用于分析多氯二苯并-对-二恶英,呋喃和类似二恶英的多氯联苯

获取原文
获取原文并翻译 | 示例
           

摘要

This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1-10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3-10%, for PCDD/Fs, and 0.2-15%, for DL-PCBs) and low instrumental limits of detection, 0.07-0.75 pg mu L-1 (for dioxins) and 0.05-0.63 pg mu L-1 (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g(-1). The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of +/- 4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g(-1), in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments. (C) 2015 Elsevier B.V. All rights reserved.
机译:本文报道了串联运行模式下气相色谱-三重四极杆质谱(GC-QqQ(MS / MS)用于多氯二苯并-对-二恶英和呋喃的定量(PCDD /环境和食品基质中的Fs,二恶英和二恶英样多氯联苯(DL-PCBs)。选择MS / MS参数以实现分析此类化合物和样品所需的高灵敏度和选择性。 (对于PCDD / Fs和DL-PCBs,RSD = 1-10%)和离子迁移率(对于PCDD / Fs,RSD = 0.3-10%,对于DL-PCBs 0.2-15%)和低仪器限经检测,获得了0.07-0.75 pg mu L-1(对于二恶英)和0.05-0.63 pg mu L-1(对于DL-PCBs)。同时使用GC-QqQ(MS / MS)和气相色谱-高分辨率质谱(GC-HRMS)也通过分析几个要塞进行低(饲料和食品),中位数(污水污泥)和高(粉煤灰)毒性当量(TEQ)浓度水平(即0.60、1.83、72.9和3609 pg)的标准样品和经认证的参考物质(CRM) / Fs)g(-1)。在所有研究样品中,GC-QqQ(MS / MS)和GC-HRMS上的总TEQ(二恶英)的结果之间的一致性在+/- 4%范围内,而DL-PCBs在浓度下的范围内饲料中0.84 pg WHO-TEQ(DL-PCBs)g(-1)的含量为0.11%。两种仪器方法都具有相似且可比较的线性,精度和准确性。 GC-QqQ(MS / MS)灵敏度要低于GC-HRMS,足以检测食品和环境样品中这些化合物的正常浓度(低至低pg水平的iLOD)。这些结果使GC-QqQ(MS / MS)适用于二恶英和DL-PCB的定量分析,是参考行业HRMS仪器的真正替代工具。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号