A capillary electrophoresis (CE) procedure with contactless conductivity detection (CD) has been developed for monitoring of neutral mono- and disaccharides in drinks and foodstuffs. The separation of a mixture of seven neutral saccharides (glucose, fructose, galactose, mannose, ribose, sucrose and lactose) employed a quartz capillary, 5 μm i.d., with an effective length of 18.3 cm, and 75 mM NaOH (pH 12.8) as the background electrolyte (BGE). The limit of detection (LOD) values obtained lied within a range from 0.4 μmolL~(-1) for lactose to 0.9μmolL~(-1) for ribose, with a separation time shorter than 140s. The procedure was successfully applied to determinations of saccharides in fruit juices, Coca-Cola, milk, red and white wines, yoghurts, honey and a foodstuff additive.
机译:已经开发了具有非接触电导检测(CD)的毛细管电泳(CE)程序,用于监测饮料和食品中的中性单糖和二糖。分离7种中性糖类(葡萄糖,果糖,半乳糖,甘露糖,核糖,蔗糖和乳糖)的混合物,采用5μmid,有效长度为18.3 cm的石英毛细管和75 mM NaOH(pH 12.8)作为本底电解液(BGE)。获得的检测限(LOD)值介于乳糖的0.4μmolL〜(-1)到核糖的0.9μmolL〜(-1)之间,分离时间短于140s。该方法已成功应用于果汁,可口可乐,牛奶,红葡萄酒和白葡萄酒,酸奶,蜂蜜和食品添加剂中糖类的测定。