International System of Units Traceable Results of Hg Mass Concentration at Saturation in Air from a Newly Developed Measurement Procedure

机译:通过新开发的测量程序获得的国际单位制可追踪的饱和空气中汞质量浓度结果

获取原文
获取原文并翻译 | 示例
       

摘要

Data most commonly used at present to calibrate measurements of mercury vapor concentrations in air come from a relationship known as the "Dumarey equation". It uses a fitting relationship to experimental results obtained nearly 30 years ago. The way these results relate to the international system of units (SI) is not known. This has caused difficulties for the specification and enforcement of limit values for mercury concentrations in air and in emissions to air as part of national or international legislation. Furthermore, there is a significant discrepancy (around 7% at room temperature) between the Dumarey data and data calculated from results of mercury vapor pressure measurements in the presence of only liquid mercury. As an attempt to solve some of these problems, a new measurement procedure is described for SI traceable results of gaseous Hg concentrations at saturation in milliliter samples of air. The aim was to propose a scheme as immune as possible to analytical biases. It was based on isotope dilution (ID) in the liquid phase with the ~(202)Hg enriched certified reference material ERM-AE640 and measurements of the mercury isotope ratios in ID blends, subsequent to a cold vapor generation step, by inductively coupled plasma mass spectrometry. The process developed involved a combination of interconnected valves and syringes operated by computer controlled pumps and ensured continuity under closed circuit conditions from the air sampling stage onward. Quantitative trapping of the gaseous mercury in the liquid phase was achieved with 11.5 μM KMnO_4 in 2% HNO_3. Mass concentrations at saturation found from five measurements under room temperature conditions were significantly higher (5.8% on average) than data calculated from the Dumarey equation, but in agreement (-1.2% lower on average) with data based on mercury vapor pressure measurement results. Relative expanded combined uncertainties were estimated following a model based approach. They ranged from 2.2% to 2.8% (k = 2). The volume of air samples was traceable to the kilogram via weighing of water for the calibration of the sampling syringe. Procedural blanks represented on average less than 0.1% of the mass of Hg present in 7.4 cm~3 of air, and correcting for these blanks was not an important source of uncertainty.
机译:当前,最常用于校准空气中汞蒸气浓度测量值的数据来自称为“ Dumarey方程”的关系。它与近30年前获得的实验结果具有拟合关系。这些结果与国际单位制(SI)相关的方式尚不清楚。作为国家或国际立法的一部分,这给规范和执行空气和空气排放中的汞浓度极限值带来了困难。此外,Dumarey数据与仅在液态汞存在下根据汞蒸气压力测量结果计算出的数据之间存在显着差异(室温下约为7%)。为了解决这些问题中的一些问题,描述了一种新的测量程序,用于在空气毫升样品中饱和状态下气态Hg浓度的SI可追踪结果。目的是提出一种尽可能不受分析偏差影响的方案。它基于富含〜(202)Hg的认证参考物质ERM-AE640在液相中的同位素稀释(ID),并在冷蒸汽产生步骤之后,通过电感耦合等离子体测量ID混合物中的汞同位素比质谱。开发的过程涉及由计算机控制的泵操作的互连阀和注射器的组合,并确保从空气采样阶段开始在封闭回路条件下的连续性。在2%HNO_3中使用11.5μMKMnO_4可以实现液相中气态汞的定量捕集。在室温条件下通过五次测量发现的饱和质量浓度比根据Dumarey方程计算的数据高得多(平均5.8%),但与基于汞蒸气压力测量结果的数据一致(平均低-1.2%)。相对扩展组合不确定性是根据基于模型的方法进行估计的。他们的范围从2.2%到2.8%(k = 2)。空气样品的体积可通过称重水来追溯到千克,以校准进样针。程序空白的平均含量不足7.4 cm〜3空气中Hg的0.1%,并且校正这些空白并不是不确定性的重要来源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号