摘要

Glass nanopore-based all-solid-state ion-selective electrodes(ISEs) have been developed to probe the distribution of ionic species at micro- or submicrometer-length scales, e.g., mapping of ion flux through micrometer-sized pores. The all-solid-state ISE was fabricated by sealing a conically etched platinum wire (d velence 25-(mu)m; radius of etched tip <10 nm) into a soda lime glass capillary. A Pt disk was exposed by gentle polishing the glass and the disk etched to form a conical pore of submicrometer dimension (radius
机译:已经开发了基于玻璃纳米孔的全固态离子选择电极(ISE),以探测离子种类在微米或亚微米长度尺度上的分布,例如,通过微米大小的孔的离子通量图。通过将圆锥形蚀刻的铂丝(距离25-μm;蚀刻尖端的半径<10 nm)密封到钠钙玻璃毛细管中来制造全固态ISE。通过轻柔地抛光玻璃来暴露Pt盘,并蚀刻该盘以形成亚微米尺寸的圆锥孔(半径<约500nm;深度<约30μm)。将Ag电镀在孔中的Pt电极上,然后轻轻地氯化以获得孔中的AgCl / Ag层。在扫描电化学显微镜实验中,使用涂有AgCl / Ag层的ISE作为高选择性Cl〜(-)探针,以绘制通过微孔的离子通量。相同的ISE也用作中性载流子掺杂的溶剂聚合物膜的基础换能器。与传统ISE(2/1)相比,用于玻璃纳米孔基全固态ISE的优化聚合物膜需要更高比例的增塑剂/聚合物(9/1)。基于IrO_(2)层在玻璃纳米孔电极底部沉积的ISE对pH的变化表现出高度敏感的响应(79.7±2.3 mV / pH),可以使用约3周。