Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study).

机译:用于估计自发压力反射敏感性的各种技术的比较(EuroBaVar研究)。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study compared spontaneous baroreflex sensitivity (BRS) estimates obtained from an identical set of data by 11 European centers using different methods and procedures. Noninvasive blood pressure (BP) and ECG recordings were obtained in 21 subjects, including 2 subjects with established baroreflex failure. Twenty-one estimates of BRS were obtained by methods including the two main techniques of BRS estimates, i.e., the spectral analysis (11 procedures) and the sequence method (7 procedures) but also one trigonometric regressive spectral analysis method (TRS), one exogenous model with autoregressive input method (X-AR), and one Z method. With subjects in a supine position, BRS estimates obtained with calculations of alpha-coefficient or gain of the transfer function in both the low-frequency band or high-frequency band, TRS, and sequence methods gave strongly related results. Conversely, weighted gain, X-AR, and Z exhibited lower agreement with all the other techniques. In addition, the use of mean BP instead of systolic BP in the sequence method decreased the relationships with the other estimates. Some procedures were unable to provide results when BRS estimates were expected to be very low in data sets (in patients with established baroreflex failure). The failure to provide BRS values was due to setting of algorithmic parameters too strictly. The discrepancies between procedures show that the choice of parameters and data handling should be considered before BRS estimation. These data are available on the web site (http://www.cbi.polimi.it/glossary/eurobavar.html) to allow the comparison of new techniques with this set of results.
机译:这项研究比较了11个欧洲中心使用不同方法和程序从同一组数据中获得的自发压力反射敏感性(BRS)估计值。在21名受试者中获得了无创血压(BP)和ECG记录,其中包括2名建立了压力感受器反射衰竭的受试者。通过包括光谱分析(11个过程)和序列方法(7个过程)的两种主要BRS估计技术的方法获得了21个BRS估计值,还有一种三角回归光谱分析方法(TRS),一种是外源的具有自回归输入法(X-AR)和一种Z方法的模型。当受试者处于仰卧位时,通过在低频或高频频段,TRS和序列方法中通过α系数或传递函数增益的计算获得的BRS估计值具有很强的相关性。相反,加权增益,X-AR和Z与所有其他技术的一致性较低。此外,在序列方法中使用平均BP代替收缩压降低了与其他估计的关系。当预期的BRS估计值在数据集中非常低时(对于已建立压力反射性衰竭的患者),某些程序无法提供结果。无法提供BRS值是由于过于严格地设置算法参数。程序之间的差异表明,在BRS估计之前应考虑参数的选择和数据处理。这些数据可在网站(http://www.cbi.polimi.it/glossary/eurobavar.html)上获得,以便将新技术与这组结果进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号