...
首页> 外文期刊>American Journal of Physiology >Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods.
【24h】

Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods.

机译:无线电遥测和尾袖套法同时测量小鼠收缩期动脉血压的比较。

获取原文
获取原文并翻译 | 示例

摘要

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.
机译:小鼠血压的无线电遥测可以准确监测收缩压,舒张压,心率和运动活动,但需要进行手术植入。长期以来,大型啮齿类动物的间接收缩压的非侵入性测量一直可用,现在对小鼠的报道更为频繁。这项研究比较了在同一只未麻醉小鼠中使用植入式无线电遥测压力传感器对小鼠的收缩期动脉血压进行的测量以及同时进行尾套测量的情况。通过诱发实验性高血压或观察到凌晨3点至6点之间的昼夜节律,扩大了用于比较的压力范围。受过训练和未经训练的尾袖操作员都使用了这两种仪器。尽一切努力遵循建议的制造商说明。使用最初的基于流量的尾袖带仪器,我们进行了671次比较(89个疗程),发现线性回归的斜率为0.118,表明一致性较差。在独立评估中,使用基于脉冲的尾袖带仪器进行了277次放射遥测测量的比较(35个疗程)。同时测量收缩压的线性回归斜率为0.98,表明一致。 Bland-Altman分析也支持我们对线性回归的解释。因此,尽管可以通过尾套或无线电遥测技术进行可靠的收缩压测量,但在我们手中,有些尾套仪器无法准确检测到血压升高。但是,这些数据不能区分这种特定于仪器的尾袖失败是由于操作员还是仪器不足引起的。我们强烈建议研究人员在进行关键的基因分型测定之前,先获得小鼠血压尾套测定的独立且同时验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号