首页> 外文期刊>Chemical Engineering Science >Oil-water two-phase flow velocity measurement with continuous wave ultrasound Doppler
【24h】

Oil-water two-phase flow velocity measurement with continuous wave ultrasound Doppler

机译:连续波超声多普勒测量油水两相流速

获取原文
获取原文并翻译 | 示例
           

摘要

A flow velocity measurement method based on continuous wave ultrasound Doppler (CWUD) and flow profile modeling is presented. A theoretical model is proposed to relate the overall superficial velocity of oil water two-phase flow with the mean velocity measured in the sensing volume of CWUD, by introducing velocity profile correlation. A CWUD measuring system was built to emit an ultrasonic wave of 1 MHz and collect the frequency shift of the reflected waves. Dynamic experiments were carried out in a horizontal pipe of inner diameter 01 50 mm with the CWUD system. Six flow patterns of horizontal oil-water two-phase flow were observed including both the water continuous flow and the oil continuous flow. According to the results, the average frequency shift in oil-water two-phase flow varies with the flow pattern. The flow velocity correlations are separately established for the oil continuous dispersed flow, water continuous dispersed flow and stratified flow, based on the analysis of flow velocity profile correction. The average relative error of the overall superficial velocity is 3.63% with a maximum relative error of 12.22%. (C) 2015 Elsevier Ltd. All rights reserved,
机译:提出了一种基于连续波超声多普勒(CWUD)和流速剖面建模的流速测量方法。提出了一个理论模型,通过引入速度剖面相关性,将油水两相流的总表观速度与在CWUD的传感体积中测得的平均速度联系起来。建造了一个CWUD测量系统,可以发射1 MHz的超声波并收集反射波的频移。使用CWUD系统在内径01 50 mm的水平管中进行动态实验。观察到水平油水两相流的六个流型,包括水连续流和油连续流。根据结果​​,油水两相流的平均频移随流型而变化。基于流速分布校正的分析,分别建立了油连续分散流,水连续分散流和分层流的流速相关性。总表观速度的平均相对误差为3.63%,最大相对误差为12.22%。 (C)2015 Elsevier Ltd.保留所有权利,

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号