Peak ascending and descending aortic blood flow velocities were measured using continuous wave Doppler ultrasound velocimetry in 30 children with coarctation or recoarctation of the aorta and in 13 control subjects. The results were compared with the arm to leg systolic blood pressure difference. The peak flow velocities in the descending aorta were significantly higher in the patients than in the control subjects and there was a close correlation with the systolic blood pressure gradient. Since there was no overlap of flow velocities between the patients and the control subjects the Doppler technique enables coarctation confidently to be excluded as well as demonstrating its presence and severity. The method is simple, rapid, independent of the condition of the aortic valve, and is applicable to neonates in whom the diagnosis of coarctation may otherwise be difficult. In older children it is useful for detecting recoarctation and following its progress, particularly in patients in whom a reliable estimate of the systolic blood pressure gradient cannot be obtained.
机译:使用连续波多普勒超声测速仪在30例主动脉缩窄或缩窄的儿童中以及13例对照受试者中测量了主动脉上升和下降的峰值速度。将结果与手臂到腿的收缩压差进行比较。患者的降主动脉峰值流速明显高于对照组,并且与收缩压梯度密切相关。由于患者和对照受试者之间没有流速重叠,因此多普勒技术能够可靠地排除缩窄,并证明了缩窄的存在和严重性。该方法简单,快速,独立于主动脉瓣的状况,适用于可能难以诊断缩窄的新生儿。在较大的儿童中,它对于检测re缩并跟踪其进展很有用,特别是在无法获得可靠的收缩压梯度估计值的患者中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号