首页> 外文期刊>Clinical microbiology and infection: European Society of Clinical Microbiology and Infectious Diseases >Identification of clinical coagulase-negative staphylococci, isolated in microbiology laboratories, by matrix-assisted laser desorption/ ionization-time of flight mass spectrometry and two automated systems
【24h】

Identification of clinical coagulase-negative staphylococci, isolated in microbiology laboratories, by matrix-assisted laser desorption/ ionization-time of flight mass spectrometry and two automated systems

机译:通过基质辅助激光解吸/电离飞行时间质谱和两个自动化系统,鉴定在微生物实验室中分离出的临床凝固酶阴性葡萄球菌

获取原文
获取原文并翻译 | 示例
           

摘要

A study was performed to compare matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF-MS), linked to a recently engineered microbial identification database, and two rapid identification (ID) automated systems, BD Phoenix (Becton Dickinson Diagnostic Systems, France) and VITEK-2 (bioMerieux, Marcy L'Etoile, France), for the ID of coagulase-negative staphylococci (CoNS). Two hundred and thirty-four clinical isolates of CoNS representing 20 species were analyzed. All CoNS isolates were characterized by sodA gene sequencing, allowing interpretation of the ID results obtained using the respective database of each apparatus. Overall correct ID results were obtained in 93.2%, 75.6% and 75.2% of the cases with the MALDI-TOF-MS, Phoenix and VITEK-2 systems, respectively. Mis-ID and absence of results occurred in 1.7% and 5.1% of the cases with MALDI-TOF-MS, in 23.1% and 1.3% with the Phoenix, and in 13.7% and 0.9% with the VITEK-2 systems, respectively. In addition, with the latter automate, 10.3% of the IDs were proposed with remote possibility. When excluding the CoNS species not included in the databases of at least one of the three systems, the final percentage of correct results, Mis-ID and absence of ID were 97.4%, 1.3% and 1.3% with MALDI-TOF-MS, 79%, 21% and 0% with the Phoenix, and 78.6%, 10.3% and 0.9% with the VITEK-2 system, respectively. The present study demonstrates the robustness and high sensitivity of our microbial identification database used with MALDI-TOF-MS technology. This approach represents a powerful tool for the fast ID of clinical CoNS isolates.
机译:进行了一项研究,以比较与最近设计的微生物识别数据库链接的基质辅助激光解吸/电离飞行时间质谱仪(MALDI-TOF-MS)和两个快速识别(ID)自动化系统BD Phoenix(Becton)法国Dickinson Diagnostic Systems和VITEK-2(法国Marcy L'Etoile的bioMerieux),用于鉴定凝固酶阴性葡萄球菌(CoNS)。分析了代表20个物种的234个CoNS临床分离株。所有的CoNS分离物均通过sodA基因测序来表征,从而可以解释使用每种仪器各自数据库获得的ID结果。使用MALDI-TOF-MS,Phoenix和VITEK-2系统分别获得93.2%,75.6%和75.2%的总体正确ID结果。使用MALDI-TOF-MS的情况下,发生错误识别和缺少结果的情况分别为1.7%和5.1%,使用Phoenix的情况分别为23.1%和1.3%,使用VITEK-2系统的情况分别为13.7%和0.9%。此外,通过后者的自动化,提出ID的10.3%的可能性很小。如果不包括三个系统中至少一个系统的数据库中未包括的CoNS种类,则使用MALDI-TOF-MS得出的正确结果,Mis-ID和ID缺失的最终百分比分别为97.4%,1.3%和1.3%,79 Phoenix分别为%,21%和0%,VITEK-2系统分别为78.6%,10.3%和0.9%。本研究证明了我们与MALDI-TOF-MS技术一起使用的微生物鉴定数据库的鲁棒性和高灵敏度。此方法代表了快速识别临床CoNS分离株的强大工具。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号