首页> 外文期刊>Nuclearmedicine >Evaluation of patients with coronary artery disease: IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results [Beurteilung von patienten mit koronarer herzkrankheit: IQ-SPECT protokoll zur darstellung der myokard- Perfusion: Vorl?ufige ergebnisse]
【24h】

Evaluation of patients with coronary artery disease: IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results [Beurteilung von patienten mit koronarer herzkrankheit: IQ-SPECT protokoll zur darstellung der myokard- Perfusion: Vorl?ufige ergebnisse]

机译:冠状动脉疾病患者的评估:心肌灌注成像的IQ-SPECT方案:初步结果

获取原文
获取原文并翻译 | 示例
           

摘要

Quantification of myocardial perfusion scintigraphy is often performed to assist physicians in detecting coronary artery disease (CAD). Modern software and hardware packages provide improvements able to shorten scan time and/or reduce administered activity, without compromising image quality in radionuclide myocardial perfusion imaging (MPI). Recently, multifocal collimators were introduced with dedicated reconstruction software, named IQ-SPECT, able to shorten considerably scan time. The aim of our study was to compare this new protocol to the already validated standard ones. Patients, methods: We enrolled 43 patients with suspected or diagnosed CAD. All patients underwent a two-days protocol radionuclide myocardial perfusion scan at rest and after a standard stress test (exercise or dipyridamole) after administering 99mTc-tetrofosmin. Images were acquired on a 2-head gamma camera and reconstructed with attenuation correction. All the images were scored using a 17-segments model by three experienced physicians, blind to clinical data and to acquisition and processing modality. Results, conclusion: No significant differences were recorded in perfusion scores on paired t-test and Wilcoxon among the full-time images reconstructed with standard protocol or IQSPECT, both overall on a 17-segments evaluation and when considering different territories of distribution. MPI with IQ-SPECT protocol can be acquired at about a quarter scan time without disagreement compared to full time scan acquisition performed with standard protocols.
机译:经常对心肌灌注显像进行定量,以协助医师检测冠状动脉疾病(CAD)。现代软件和硬件软件包提供了能够缩短扫描时间和/或减少管理活动的改进,而又不损害放射性核素心肌灌注成像(MPI)的图像质量。最近,多焦点准直仪被引入了名为IQ-SPECT的专用重建软件,能够大大缩短扫描时间。我们研究的目的是将该新协议与已经验证的标准协议进行比较。患者,方法:我们招募了43名怀疑或诊断为CAD的患者。所有患者均在静息时以及在施用99mTc-四氟膦之后进行标准压力测试(运动或双嘧达莫)后接受为期两天的放射性核素心肌灌注扫描。在2头伽马相机上采集图像,并通过衰减校正进行重建。由三位经验丰富的医师使用17段模型对所有图像进行评分,这些模型对临床数据以及采集和处理方式都不了解。结果,结论:用标准方案或IQSPECT重建的全时图像在配对t检验和Wilcoxon上的灌注评分中均无显着差异,总体上在17段评估中以及考虑不同分布区域时均如此。与使用标准协议执行的全时扫描采集相比,具有IQ-SPECT协议的MPI可以在大约四分之一的扫描时间进行采集而不会出现分歧。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号