首页> 外文期刊>胸部外科 >低体重新生児における体外循環非使用心房中隔欠損作成術
【24h】

低体重新生児における体外循環非使用心房中隔欠損作成術

机译:低体重新生儿的体外循环不使用性房间隔缺损的形成

获取原文
获取原文并翻译 | 示例
           

摘要

We report a surgical technique for off-pump atrial septectomy using a Rongeur forceps in the case of a newborn infant weighing less than 2,000 grams. The 6-day-old patient suffered from hypoplastic left heart syndrome with a restrictive interatrial communication. A purse-string suture was placed on the right atrium. A hand-made dull-tipped cannula was inserted into the right atrium through the suture to probe the interatrial communication. Monitoring the pressure at the tip of cannula, we could clearly determine when the cannula tip entered the left atrium. Then, a Rongeur forceps was inserted instead of the cannula, and used to bite into the interatrial septum. It was removed slowly together with the resected atrial specimen. In this manner, an atrial septectomy can be performed without cardiopulmonary bypass ; this is far safer and easier than other procedures, such as the Blalock-Hanlon technique. This method can be performed in a small neonate as well as an older infant in whom balloon atrial septostomy is difficult.
机译:我们报告了在体重小于2,000克的新生儿情况下使用Rongeur钳进行非体外循环房间隔手术的技术。这位6天大的患者患有发育不良的左心综合征,并且房间通讯受限。在右心房放置一个荷包缝线。通过缝线将手工制作的钝尖插管插入右心房,以探查房间隔。监测插管尖端的压力,我们可以清楚地确定插管尖端何时进入左心房。然后,插入Rongeur钳代替套管,并咬入房间隔。将其与切除的心房标本一起缓慢取出。这样,无需进行体外循环就可以进行房间隔切除术。这比其他程序(例如Blalock-Hanlon技术)更安全,更容易。该方法可以在难以进行球囊房间隔造口术的小型新生儿和大婴儿中进行。