首页> 外文期刊>材料 >Application of Detection Technique of Reinforcing Steel Corrosion in Concrete Using AC Impedance Method to Specimens Exposed at Seashores for Seven Years
【24h】

Application of Detection Technique of Reinforcing Steel Corrosion in Concrete Using AC Impedance Method to Specimens Exposed at Seashores for Seven Years

机译:交流阻抗法检测钢筋锈蚀钢筋混凝土技术在近海样本中的应用七年

获取原文
获取原文并翻译 | 示例
       

摘要

The applicability of non-destructive corrosion detection using AC impedance method to the specimens is investigated, in which test specimens have been exposed to seashore environment for seven years at three different sites, Matsumae in Hokkaido, Nagoya and Ishikawa in Okinawa. The followings are main conclusions derived from the tests results: a) Steel corrosion in concrete and cracks in concrete cover due to steel corrosion were observed after seven years exposure. Steels in the specimens exposed to tidal condition in Nagoya corroded considerably. On the other hand, steels in the specimens exposed to seaside area in Matsumae and Okinawa corroded a little. b) The corrosion detection technique using AC impedance method can be well used to estimate amounts of steel corrosion of specimens irrespective of environmental conditions.
机译:研究了使用交流阻抗法进行的无损腐蚀检测在样品上的适用性,其中在北海道的松前,名古屋和冲绳的石川市的三个不同地点,将测试样品暴露于沿海环境达七年之久。以下是从测试结果得出的主要结论:a)暴露7年后,观察到混凝土中的钢筋腐蚀和钢筋腐蚀引起的混凝土表层裂缝。名古屋暴露于潮汐条件下的标本中的钢腐蚀严重。另一方面,暴露于松前和冲绳海滨地区的标本中的钢材略有腐蚀。 b)无论环境条件如何,使用交流阻抗法的腐蚀检测技术都可以很好地用于估计试样的钢腐蚀量。