Introduction: Despite increased automation in the field of radiation therapy, the need to perform monitor unit calculations manually still exists for a small number of clinical situations. Challenges in maintaining the skill of performing infrequently occurring clinical tasks have been identified among other health professions, but no study has been performed for similar issues in radiation therapy. The aim of this study was to explore radiation therapists' (RT) perceived changes in comfort level to perform manual calculations (MC), an infrequently occurring clinical task, and to evaluate factors that may have influenced the change in comfort level.Methods and Materials: The study sample consisted of RTs working within the radiation therapy department of a cancer hospital. A questionnaire soliticing RTs' comfort level with MC and potential influencing factors was sent to each participant. The difference in responses based on key study variables, including initial mastery of MC, ongoing exposure to MC, recent exposure to MC, and MC continuing education, was analyzed. Jxuaddition, a wave analysis was performed to determine whether the responses gathered with the questionnaire were representative of those who did not respond.Results: Fifty-one responses were obtained. The wave analysis suggested that our study results may reflect the views of those of RTs who were eligible to participate, but did not respond. Ninety percent of the participants reported that their comfort level in performing MC had decreased over the years. A significantly smaller proportion of participants reported being comfortable with orthovoltage MC (14%) compared to other types of MC (75-84%). Participants' years of work experience did not appear to influence their comfort level in performing MC. A higher proportion of participants that had recent or ongoing exposure to MC, including those that performed a MC within the last 12 months, worked in dosimetry, were engaged in on-call activities, or were engaged in continuing education on MC, reported being more comfortable in MC than those participants who did not engage in such activities (91%-92% vs. 47%-71%, P< .001). Discussion/Conclusion: Initial mastery and ongoing exposure were identified in the literature as important factors that influence practitioners' ability in performing clinical tasks. Although initial mastery was found to influence comfort level in performing MC, our study also revealed that ongoing exposure may be relatively more important. Lessons drawn from this study will become more important to the field of radiation therapy as more manually performed clinical tasks become less frequent over time. To address potential reduction in RTs' ability in performing this infrequent clinical task, individual radiotherapy departments have historically put in place effective strategies to assure accuracy. Yet, alternatives to performing MC should be explored in order to maximize safety, efficiency, and quality of patient care.
机译:简介:尽管放射治疗领域的自动化程度有所提高,但对于少数临床情况,仍然需要手动执行监测单位计算。在其他卫生专业人员中,已经确定了保持执行不经常发生的临床任务的技能方面的挑战,但是还没有针对放射治疗中类似问题进行研究。这项研究的目的是探索放射治疗师(RT)感知到的舒适度变化,以执行手动计算(MC),一项罕见的临床任务,并评估可能影响舒适度变化的因素。 :研究样本由癌症医院放射治疗部门内的RT组成。向每位参与者发送了问卷调查表,以收集RT的舒适度和MC以及潜在的影响因素。根据主要研究变量(包括对MC的初步掌握,对MC的持续接触,对MC的近期接触以及对MC的继续教育)的回答差异进行了分析。进行了波动分析,以确定问卷收集的回答是否代表未回答的结果。结果:获得五十一个回答。波动分析表明,我们的研究结果可能反映了有资格参加但没有回应的RT人士的观点。百分之九十的参与者报告说,多年来他们进行MC的舒适度有所下降。与其他类型的MC(75-84%)相比,报告称对正电压MC感到舒适的参与者比例要小得多(14%)。参与者多年的工作经验似乎并未影响他们进行MC的舒适度。据报道,最近或正在进行MC的参与者比例较高,包括最近12个月内进行过MC的参与者,剂量学方面的工作人员,正在进行的待命活动或进行MC继续教育的参与者,据报道更多与未参加此类活动的参与者相比,他们的MC舒适(91%-92%对47%-71%,P <.001)。讨论/结论:最初的掌握和持续的接触在文献中被认为是影响从业人员执行临床任务能力的重要因素。尽管发现最初的掌握会影响执行MC的舒适度,但我们的研究还表明,持续暴露可能相对更重要。这项研究的经验教训对于放射治疗领域将变得越来越重要,因为随着时间的流逝,越来越多的手动执行临床任务变得越来越少。为了解决RTs执行此罕见临床任务的能力的潜在降低,历史上各个放射治疗部门都制定了有效的策略来确保准确性。但是,应该探索执行MC的替代方法,以最大程度地提高患者护理的安全性,效率和质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号