PURPOSE: This retrospective study was performed to investigate the authors' clinical observations that suggest that Tesio hemodialysis catheters may initially have suboptimal blood flow rates, which improve spontaneously after several hemodialysis treatment sessions. MATERIALS AND METHODS: Sixty Tesio twin hemodialysis catheters were placed in 49 patients during a 2-year period. Thirty twin catheters were placed by radiologists, and 30 were placed by surgeons. The catheter blood flow rates and catheter line pressures, which were recorded during each of the first five hemodialysis treatment sessions, were reviewed and analyzed to determine the performance of each catheter during the first five hemodialysis treatments. In addition, the authors compared the site of catheter placement and responsible service (surgery or radiology) using this catheter performance data. RESULTS: Twenty-six catheters (43%) provided adequate blood flow (250 mL/min) throughout the first five hemodialysis sessions. Twenty-six catheters (43%) had inadequate or variable blood flow rates, some of which improved without intervention. Eight catheters (13%) required an intervention before the first five hemodialysis sessions had been completed. Right-sided catheters performed better than left-sided catheters. There was no difference in performance between catheters placed by surgeons and those placed by radiologists. CONCLUSION: This investigation supports the authors' suspicion that some Tesio catheters may have inadequate initial performance but the blood flows can improve, without intervention, during the first five hemodialysis sessions/2 weeks of use.
机译:目的:进行这项回顾性研究,以调查作者的临床观察结果,这些结果表明Tesio血液透析导管最初可能具有次优的血流速度,在经过几次血液透析治疗后,其自发性改善。材料与方法:在两年期间,对49例患者放置了60根Tesio双血液透析导管。放射科医生放置了30条双导管,外科医生放置了30条双导管。回顾并分析在前五个血液透析治疗期间的每一个过程中记录的导管血液流速和导管管路压力,以确定在前五个血液透析治疗期间每个导管的性能。此外,作者使用该导管性能数据比较了导管放置和负责任服务(手术或放射学)的部位。结果:二十六个导管(43%)在前五个血液透析过程中提供了足够的血流量(250 mL / min)。 26根导管(43%)的血流速度不足或变化,其中一些未经干预即可改善。在完成前五个血液透析疗程之前,需要八个导管(13%)进行干预。右侧导管的性能优于左侧导管。外科医生放置的导管与放射科医生放置的导管之间的性能没有差异。结论:这项研究支持作者的怀疑,即某些Tesio导管可能没有足够的初始性能,但在使用血液透析的前5个疗程/ 2周内,无需干预即可改善血流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号