Purpose: To assess the effectiveness of flow reversal as an alternative means of cerebral protection by using transcranial Doppler recordings and diffusion-weighted imaging (DWI) as surrogate markers of brain injury. Materials and Methods: Eighteen patients with symptomatic carotid artery disease were recruited. Magnetic resonance imaging was performed before the intervention and at 3 and 24 hours and 30 days after the intervention to detect new ischemic lesions with DWI. Transcranial Doppler recordings were made during the procedure to assess for microembolic signals (MESs). Data were compared against data from a historical control cohort of patients who underwent CAS placement with or without filter protection (n = 15 each) under the same protocol in a different study. Results: There were fewer periprocedural new lesions on DWI in the reverse-flow cohort compared with the historical control cohort with filter protection (P =.084). Reverse flow revealed significantly fewer MESs during the whole procedure compared with the filter-protected group (P =.01) but not the unprotected group (P =.55). There was a marked decrease in MES counts for reverse flow protection during the embologenic stages of the procedure (P =.004). Conclusions: Use of the reverse flow device was associated with fewer overall lesions on DWI and proportionately fewer positive scans compared with the use of filter-type devices (P =.08, not significant). Transcranial Doppler recordings demonstrated a significant reduction in embolization to the brain during carotid artery stent placement with the use of reverse-flow cerebral protection.
机译:目的:通过使用经颅多普勒记录和弥散加权成像(DWI)作为脑损伤的替代指标,评估逆流作为替代性脑保护手段的有效性。材料与方法:招募了18例有症状的颈动脉疾病的患者。干预前和干预后3、24小时和30天进行磁共振成像,以检测DWI的新的缺血性病变。在手术过程中进行经颅多普勒记录,以评估微栓塞信号(MES)。将数据与来自历史对照队列的患者的数据进行比较,该队列在不同研究中在相同方案下接受或不接受滤器保护(每例n = 15)进行CAS放置的患者。结果:与具有过滤器保护功能的历史对照队列相比,逆流队列中DWI的围手术期新病变较少(P = .084)。与过滤器保护组(P = .01)相比,逆流显示整个过程中的MES明显减少(P = .01),而非未保护组(P = .55)。在该过程的栓塞形成阶段,用于逆流保护的MES计数显着降低(P = .004)。结论:与使用过滤器类型的设备相比,使用逆流设备与DWI上的总体病变更少,阳性扫描成比例地减少有关(P = .08,不显着)。经颅多普勒记录显示,通过使用逆流脑保护装置,在颈动脉支架置入过程中对大脑的栓塞作用显着减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号