摘要

Oil refinery wastewater was sequentially treated in a moving-bed biofilm reactor (MBBR) and a slow-rate sand filter (SF) in order to obtain an effluent with adequate characteristics for downstream reverse osmosis (RO) operation. Experiments were conducted in bench scale units and the results showed that the MBBR was able to remove 90% chemical oxygen demand (COD), 75% NH_4~+, 95% phenols, operating with a hydraulic retention time (HRT) of 9 h. Additional removal of COD (15-40%) and ammonia (30-60%) was achieved in the slow-rate SF that was also effective for removing microorganisms. The silt density index (SDI) of the treated wastewater (4.5) was below the maximum limit recommended for RO operation. The quality of the effluent from the combined treatment system (MBBR+SF) was already adequate for cooling tower make-up. The RO produced an effluent with quality compatible with that required for use in boilers
机译:炼油厂废水在移动床生物膜反应器(MBBR)和慢速砂滤器(SF)中进行顺序处理,以获得具有用于下游反渗透(RO)操作的足够特性的废水。实验在实验室规模的装置上进行,结果表明,MBBR能够以9 h的水力停留时间(HRT)去除90%的化学需氧量(COD),75%NH_4〜+,95%的酚。在慢速SF中,还可以额外去除COD(15-40%)和氨(30-60%),这对于去除微生物也很有效。处理后的废水的淤泥密度指数(SDI)(4.5)低于推荐用于RO操作的最大限值。组合处理系统(MBBR + SF)出水的质量已经足以满足冷却塔的补充要求。 RO产生的废水的质量与锅炉所需的质量兼容