A sensitive and simple method for flame atomic absorption spectrometric determination of Cu, Fe, Pb, Ni and Mn after separation/preconcentration by sorbing 8-hydroxiquinoline (OXINE) complex of analytes on the Diaion HP-20 column has been established. The metal/oxine complexes were quantitatively retained on the Diaion HP-20 at pH 9. Metals retained on the column were quantitatively (<95%) eluted with 1 M HNO_3 in acetone. The accuracy of the method was demonstrated by the analysis of a stream sediment standard reference material (GBW7309) sample and by recovery on spiked samples. The method was applied to the determination of copper, iron, lead, nickel and manganese in drinking water samples and good results were obtained (Recoveries >95%, relative standard deviations <9%, relative error <3%).
机译:建立了一种灵敏,简便的方法,该方法通过在Diaion HP-20色谱柱上吸附分析物的8-羟基喹啉(OXINE)络合物进行分离/预富集,然后通过火焰原子吸收光谱法测定Cu,Fe,Pb,Ni和Mn。在pH值为9的情况下,将金属/ oxine复合物定量保留在Diaion HP-20上。用在丙酮中的1 M HNO_3定量洗脱(<95%)保留在色谱柱上的金属。该方法的准确性通过分析河流沉积物标准参考物质(GBW7309)样品和加标样品的回收率来证明。该方法用于饮用水样品中铜,铁,铅,镍和锰的测定,结果良好(回收率> 95%,相对标准偏差<9%,相对误差<3%)。