The purpose of this study was to compare the effect of ferrule with different heights on the stress distribution of dentin and the restoration-tooth complex, using the finite element stress analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with an all-ceramic crown were prepared. Three-dimensional models were varied in their ferrule height (NF: no ferrule, 1F: 1-mm ferrule, and 2F: 2-mm ferrule). A 300-N static occlusal load was applied to the palatal surface of the crown with a 135 degrees angle to the long axis of the tooth. In addition, two post and core materials with different elastic modulus were evaluated. The differences in stress transfer characteristics of the models were analyzed. Maximum stresses were concentrated on force application areas (32.6-32.8 MPa). The stress values observed with the use of a 2-mm ferrule (14.1/16.8 MPa) were lower than the no-ferrule design (14.9/17.1 MPa) for both the glass fiber-reinforced and zirconium oxide ceramic post systems, respectively. The stress values observed with zirconium oxide ceramic were higher than that of glass fiber-reinforced post system. The use of a ferrule in endodontically treated teeth restored with an all-ceramic post-and-core reduces the values of von Mises stresses on tooth-restoration complex. At rigid zirconium oxide ceramic post system, stress levels, both at dentin wall and within the post, were higher than that of fiber posts.
机译:这项研究的目的是使用有限元应力分析方法,比较不同高度的套圈对牙本质和修复牙复合体应力分布的影响。准备了三维有限元模型,模拟了用全瓷冠修复的牙髓治疗上颌中切牙。三维模型的插芯高度有所不同(NF:无插芯,1F:1-mm插芯,2F:2-mm插芯)。将300-N静态咬合载荷施加到牙冠的pa表面,与牙齿的长轴成135度角。另外,评估了具有不同弹性模量的两种柱芯材料。分析了模型中应力传递特性的差异。最大应力集中在施力区域(32.6-32.8 MPa)上。对于玻璃纤维增​​强和氧化锆陶瓷立柱系统,使用2 mm套圈(14.1 / 16.8 MPa)观察到的应力值分别低于无套圈设计(14.9 / 17.1 MPa)。用氧化锆陶瓷观察到的应力值要比玻璃纤维增​​强的柱后系统高。在用全陶瓷桩核修复的牙髓治疗牙齿中使用密封垫圈,可以降低von Mises对牙齿修复复合物的应力值。在刚性氧化锆陶瓷桩系统中,牙本质壁处和桩内部的应力水平都高于纤维桩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号