Source localization of interictal epileptiform discharges: comparison of three different techniques to improve signal to noise ratio.

机译:发作性癫痫样放电的声源定位:三种不同技术的比较,以提高信噪比。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To investigate the localization accuracy of low-resolution electromagnetic tomography (LORETA) for mesial temporal interictal epileptiform discharges (IED) using a new relative averaging (RELAVG) technique for noise reduction. METHODS: We analyzed 19 patterns of mesial temporal IED recorded simultaneously with scalp and foramen ovale (FO) electrodes in 15 consecutive patients who underwent presurgical assessment for intractable temporal lobe epilepsy. The scalp signals were time-locked to the peak activity in the FO electrode recordings and source modeling was performed using the RELAVG technique. Random noise of various amounts was then applied. The results were compared to intracranial data obtained from the FO electrode recordings and to LORETA source solutions obtained using two other approaches to improve signal to noise ratio (SNR): statistical non-parametric mapping (SNPM) and the commonly applied averaging (AVG) technique. RESULTS: The RELAVG technique allowed for reasonable mesial temporal localization in 52.6% (10/19) of IED patterns, compared with 73.7% (14/19) using SNPM. The AVG technique provided no strictly mesial temporal solutions. Nine of the IED patterns revealed relative current density quotient changes >10; all of these were accurately localized by RELAVG into mesial temporal structures. Increasing amounts of white and physiological noise had no influence on the accuracy of RELAVG and SNPM solutions, whereas AVG source reconstructions became progressively spurious. CONCLUSION: The RELAVG technique and SNPM, but not the commonly used AVG technique, allow for reasonable source localization of mesial temporal IED. SNPM is the most accurate but also the most time-consuming noise reduction technique. SIGNIFICANCE: The RELAVG LORETA technique might provide a simple and fast semi-quantitative alternative for localizing IED with low single to noise ratio.
机译:目的:使用一种新的相对平均技术(RELAVG)来研究低分辨率电磁层析成像(LORETA)对颞叶间壁癫痫样放电(IED)的定位精度。方法:我们分析了15例连续的患者进行了术前评估的顽固性颞叶癫痫发作时,同时记录的19种模式的颞叶IED与头皮和卵圆孔(FO)电极同时记录。头皮信号被时间锁定到FO电极记录中的峰值活性,并使用RELAVG技术进行源建模。然后施加各种数量的随机噪声。将结果与从FO电极记录获得的颅内数据以及使用其他两种改善信噪比(SNR)的方法获得的LORETA源解决方案进行了比较:统计非参数映射(SNPM)和常用平均(AVG)技术。结果:RELAVG技术允许在52.6%(10/19)的IED模式中进行合理的近中颞叶定位,而使用SNPM的比例为73.7%(14/19)。 AVG技术没有提供严格的中间时间解决方案。 9个IED模式显示相对电流密度商变化> 10;所有这些都通过RELAVG精确定位到了颞中叶结构中。白噪声和生理噪声的增加对RELAVG和SNPM解决方案的准确性没有影响,而AVG源重构逐渐变得虚假。结论:RELAVG技术和SNPM,但不是常用的AVG技术,允许对颞叶IED进行合理的源定位。 SNPM是最准确但也是最耗时的降噪技术。重要性:RELAVG LORETA技术可能为单低噪声比的IED定位提供一种简单快捷的半定量替代方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号