To date, the standardized method for glycerol quantification in biodiesel production utilizes gas chromatography (GC); however, availability to manufacturers and instrumentation cost limits GC as an analytical method for general quality enforcement among producers. The method developed here is a bench top technique for quantitative determination of glycerol in biodiesel, with practical application in pharmaceutical and environmental quality control. The method extracts the glycerol contaminant from biodiesel using a normal phase solid phase extraction column (SPE). The protocol proceeds by rinsing with hexane to remove residual methyl esters, then collecting the glycerol with water. The aqueous extract is analyzed spectrophotometrically by an anthrone coloring reagent. Use of 2-g SPE columns and the solvent system developed has achieved 85% glycerol recovery. The assay applied has a detection range of 0.004-0.400% free glycerol, comparable to the established American Society of Testing and Materials (ASTM) D 6584-07 GC technique. Results were confirmed by GC and high-pressure liquid chromatography (HPLC). The bench top technique reduces the costs of operation relative to current methods, completes analysis in proficient time, requires minimal labor, and has analytical limits comparable to existing standard methods of biofuel analysis.
机译:迄今为止,生物柴油生产中甘油定量的标准化方法是利用气相色谱法(GC)进行的。但是,制造商的可用性和仪器成本限制了GC作为生产商之间一般质量执行的一种分析方法。本文开发的方法是一种台式技术,用于定量测定生物柴油中的甘油,在制药和环境质量控制中具有实际应用。该方法使用正相固相萃取柱(SPE)从生物柴油中萃取甘油污染物。该方案通过用己烷冲洗以除去残留的甲酯进行,然后用水收集甘油。用蒽酮着色剂分光光度法分析水提取物。使用2 g SPE色谱柱和开发的溶剂系统可实现85%的甘油回收率。所应用的测定法具有0.004-0.400%游离甘油的检测范围,与已建立的美国材料试验学会(ASTM)D 6584-07 GC技术相当。通过GC和高压液相色谱法(HPLC)确认结果。相对于当前方法,台式技术降低了操作成本,可以在足够的时间内完成分析,需要最少的人工,并且具有与现有生物燃料分析标准方法相当的分析极限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号