首页> 外文期刊>Journal of the American Society of Echocardiography: official publication of the American Society of Echocardiography >Semiautomated detection and quantification of aortic plaques from three-dimensional transesophageal echocardiography
【24h】

Semiautomated detection and quantification of aortic plaques from three-dimensional transesophageal echocardiography

机译:三维经食管超声心动图对主动脉斑块的半自动检测和定量

获取原文
获取原文并翻译 | 示例

摘要

Background Aortic atherosclerosis is a risk factor for cerebrovascular events. Two-dimensional transesophageal echocardiographic quantification of descending aortic plaques is time-consuming and underestimates plaque burden. The aim of this study was to assess the feasibility and accuracy of a novel semiautomated program that uses three-dimensional (3D) transesophageal echocardiography to identify and quantify aortic plaque severity as determined by plaque thickness, volume, and number. The relationship between maximum plaque thickness and volume was also examined. Methods Descending aortic 3D transesophageal echocardiographic images from 58 patients were analyzed for plaque thickness, volume, and number using semiautomated custom software. The reference standard was manual assessment by an expert reader using 3D multiplanar reconstructions. Agreement and κ values were calculated to determine the program's accuracy against the reference standard. Correlation and bias were examined using linear regression and Bland-Altman statistics. Pearson's correlation was used to examine the relationship between maximum plaque thickness and volume. Results Analysis was possible in all patients. Overall agreement for the absolute presence or absence of plaque per patient was 95%. Agreement regarding the number of plaques per patient and plaque severity was high at 95% and 85%, respectively. Plaque volume was slightly underestimated by the program compared with manual measurements. The correlation between plaque thickness and volume was 0.56. Conclusions The results of this study demonstrate that semiautomated plaque analysis of 3D transesophageal echocardiographic descending aortic data sets is feasible and accurate in determining plaque severity as measured by plaque thickness, volume, and number. This methodology allows the standardization of plaque quantification, which will improve its utility in clinical trials. A greater understanding of the importance of plaque thickness versus volume is needed.
机译:背景主动脉粥样硬化是脑血管事件的危险因素。降主动脉斑块的二维经食管超声心动图定量分析既费时,又低估了斑块负担。这项研究的目的是评估一种新颖的半自动化程序的可行性和准确性,该程序使用三维经食道超声心动图(3D)来识别和量化由斑块厚度,体积和数量决定的主动脉斑块严重程度。还检查了最大噬菌斑厚度和体积之间的关系。方法使用半自动定制软件分析58例降主动脉的3D食管超声心动图图像的斑块厚度,体积和数量。参考标准是使用3D多平面重建的专家阅读器进行的手动评估。计算一致性和κ值,以确定程序相对于参考标准的准确性。使用线性回归和Bland-Altman统计数据检查相关性和偏差。皮尔逊相关性用于检查最大噬菌斑厚度和体积之间的关系。结果所有患者均可以进行分析。每位患者绝对存在或不存在牙菌斑的总体一致性为95%。关于每个患者的斑块数量和斑块严重程度的共识分别很高,分别为95%和85%。与手动测量相比,程序对斑块的体积略有低估。斑块厚度与体积之间的相关性为0.56。结论这项研究的结果表明,对3D经食道超声心动图降主动脉数据集进行半自动斑块分析,可通过斑块厚度,体积和数量确定斑块严重程度,是可行且准确的。这种方法可以实现斑块定量的标准化,从而提高其在临床试验中的效用。需要对斑块厚度对体积的重要性有更深入的了解。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号