首页> 外文期刊>Journal of Pharmacy and Pharmacology >High-speed digital imaging method for ciliary beat frequency measurement.
【24h】

High-speed digital imaging method for ciliary beat frequency measurement.

机译:高速数字成像方法用于纤毛搏动频率测量。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to develop a high-speed digital imaging system and related software for ciliary beat frequency (CFB) analysis in order to establish an automated and reliable method that is observer independent and faster compared to the conventional computerized microscope photometry method. Using primary human nasal epithelial cell cultures, the CBF was recorded with a computerized microscope photometry system and a high-speed digital imaging system. To obtain a wide range of frequencies, glycocholate (0.5%) and chlorocresol (0.005%) were used as ciliostimulatory and cilio-inhibitory reference compounds, respectively. The mean values in hertz (+/- s.d.) obtained with the photometry and high-speed digital imaging systems were: controls 8.2 +/- 0.9 and 7.9 +/- 1.1; chlorocresol 5.0 +/- 0.9 and 5.1 +/- 1.1; glycocholate 9.8 +/- 1.0 and 9.7 +/- 0.8. A similar increase (by 20 and 24%) and decrease (by 38 and 35%) in CBF was determined by the two methods after glycocholate and chlorocresol treatment, respectively. The mean difference between the photometry and high-speed digital imaging methods was 0.2 +/- 0.6 Hz, and the Bland-Altman limits of agreement were from -1.0 to +1.4 Hz, suggesting that the results obtained by these two methods could be used interchangeably. These results show the reliability of the high-speed digital imaging system and the software developed for in-vitro CBF measurements. The advantages of the system include: (i) fast data acquisition and calculation, (ii) whole field automated CBF analysis and (iii) reduction in selection bias.
机译:这项研究的目的是开发一种高速数字成像系统和相关软件来进行纤毛搏动频率(CFB)分析,以建立一种自动可靠的方法,与传统的计算机显微镜光度法相比,它独立于观察者,而且速度更快。使用原代人鼻上皮细胞培养物,用计算机显微镜光度测定系统和高速数字成像系统记录脑血流。为了获得宽范围的频率,分别使用甘草酸盐(0.5%)和氯甲酚(0.005%)作为纤毛刺激和纤毛抑制参考化合物。用光度法和高速数字成像系统获得的以赫兹(+/- s.d.)为单位的平均值为:对照8.2 +/- 0.9和7.9 +/- 1.1;氯甲酚5.0 +/- 0.9和5.1 +/- 1.1;糖胆酸9.8 +/- 1.0和9.7 +/- 0.8。两种方法分别测定了糖胆酸盐和氯甲酚处理后CBF的相似增加(增加20%和24%)和减少(分别减少38和35%)。光度法和高速数字成像方法之间的平均差为0.2 +/- 0.6 Hz,并且Bland-Altman一致性极限为-1.0至+1.4 Hz,这表明可以使用这两种方法获得的结果可以互换这些结果表明了高速数字成像系统的可靠性以及为体外CBF测量开发的软件。该系统的优点包括:(i)快速数据采集和计算,(ii)全场自动CBF分析和(iii)减少选择偏差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号