...
首页> 外文期刊>Journal of the American College of Cardiology >Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution.
【24h】

Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution.

机译:非侵入性冠状动脉成像的诊断准确性,采用16层切片螺旋计算机断层扫描,时间分辨率为188 ms。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: The aim of our study was to evaluate the diagnostic accuracy of 16-multi-detector spiral computed tomography (MDCT) with 188 ms temporal resolution. BACKGROUND: Because of rapid technical innovations, MDCT coronary imaging has significantly improved in the last five years. Recent results indicate a high diagnostic accuracy, especially in patients with clinical suspicion of coronary artery disease (CAD). METHODS: A total of 72 consecutive patients (30 women, 42 men, age 64 +/- 10 years) scheduled for invasive coronary angiography (ICA) because of suspected CAD were additionally studied by MDCT (Sensation 16 Speed 4D, Siemens, Forchheim, Germany). Thirty-seven of 72 patients (51%) received an additional beta-blockade before MDCT because of heart rates >65 beats/min. The MDCT scans were analyzed regarding the presence of coronary artery lesions. Results were compared with ICA. RESULTS: All 72 scans showed diagnostic image quality (heart rate: 64.1 +/- 9.2 beats/min, calcium mass: 86 +/- 156 mg). Thirteen coronary segments were evaluated in each patient. Sixty-two of 936 (6.6%) segments showed a nondiagnostic image quality. All segments were included in the analysis. A total of 117 relevant lesions (diameter stenosis >50%) were detected using ICA, and 96 of 117 (82%) were detected by MDCT. Sensitivity, specificity, and positive and negative predictive values for the whole study group were as follows: 82%, 98%, 87%, and 97%, respectively. The correct clinical diagnosis of presence or absence of significant CAD was obtained in 65 of 72 (90%) patients. All stenoses were detected by MDCT in 52 of 72 (72%) patients. CONCLUSIONS: Our results indicate a high diagnostic accuracy of 16-slice MDCT with improved temporal resolution.
机译:目的:我们的研究目的是评估188毫秒时间分辨率的16层螺旋CT的诊断准确性。背景:由于快速的技术创新,MDCT冠状动脉成像在过去五年中已得到显着改善。最近的结果表明,诊断准确性很高,尤其是在临床怀疑冠心病(CAD)的患者中。方法:MDCT(Sensation 16 Speed 4D,Siemens,Forchheim,Sensation 16 Speed 4D)对另外72例连续的患者(30例女性,42例男性,年龄64 +/- 10岁)因疑似CAD而进行了计划的侵入性冠状动脉造影(ICA)研究。德国)。 72例患者中有37例(51%)由于心率> 65次/分钟而在MDCT之前接受了额外的β受体阻滞。分析了MDCT扫描有关冠状动脉病变的存在。将结果与ICA进行比较。结果:所有72次扫描均显示诊断图像质量(心率:64.1 +/- 9.2次/分钟,钙质量:86 +/- 156毫克)。每位患者评估了13个冠状动脉节段。 936个细分市场中有62个(6.6%)显示出无法诊断的图像质量。所有细分均包括在分析中。使用ICA总共检测到117个相关病变(直径狭窄> 50%),而通过MDCT检测到117个相关病变中的96个(82%)。整个研究组的敏感性,特异性以及阳性和阴性预测值如下:分别为82%,98%,87%和97%。在72名(90%)患者中,有65名获得了关于是否存在明显CAD的正确临床诊断。通过MDCT在72名患者中的52名(72%)中检测到所有狭窄。结论:我们的结果表明16层MDCT具有较高的诊断准确性,并具有改进的时间分辨率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号