...
首页> 外文期刊>Journal of the American Society for Mass Spectrometry >Automated precursor ion exclusion during LC-MS/MS data acquisition for optimal ion identification
【24h】

Automated precursor ion exclusion during LC-MS/MS data acquisition for optimal ion identification

机译:在LC-MS / MS数据采集过程中自动排除前体离子,以实现最佳离子识别

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is widely used for characterizing multiple samples of complex mixtures with similar compositions. This article addresses a data acquisition strategy for collecting a maximal number of unique, high-quality MS/MS during LC-MS/MS analysis of multiple samples. Based on the concept that a component only needs to be identified once when analyzing multiple samples with similar compositions, an automated intersample data-dependent acquisition strategy was developed. The strategy is based on precursor ion exclusion (PIE) and is implemented in MassAnalyzer in an automated fashion for Thermo Scientific (San Jose, CA, USA) mass spectrometers. In this method, MassAnalyzer submits one sample at a time to the sample queue. After data acquisition of each sample, MassAnalyzer automatically analyzes the data to generate a PIE list based on the MS/MS precursor ions, merges this list with the list generated from previous runs, adds the list to the MS method file, and submits the next sample to the queue. The PIE list contains both m/z value and time window for each precursor ion, and is generated intelligently so that if an MS/MS is insufficient for identifying the peak of interest, it will be collected again near the top of the peak in the next run. Therefore, the strategy maximizes both quality and the number of unique MS/MS. When automated PIE was used to acquire LC-MS/MS data of an antibody tryptic digest and a soy hydrolysate sample, the number of identified ions increased by 52 % and 93 %, respectively, compared with data acquired without using PIE.
机译:液相色谱-串联质谱(LC-MS / MS)被广泛用于表征具有相似组成的复杂混合物的多个样品。本文介绍了一种数据采集策略,用于在对多个样品进行LC-MS / MS分析期间收集最大数量的独特,高质量的MS / MS。基于在分析具有相似成分的多个样品时只需要识别一次组分的概念,开发了一种自动的基于样品间数据的采集策略。该策略基于前驱物离子排阻(PIE),并在Thermo Scientific(美国加利福尼亚州圣何塞)质谱仪中以自动化方式在MassAnalyzer中实施。在这种方法中,MassAnalyzer一次将一个样品提交到样品队列。采集每个样品的数据后,MassAnalyzer会自动分析数据以基于MS / MS前驱体离子生成一个PIE列表,将该列表与先前运行生成的列表合并,将该列表添加到MS方法文件中,然后提交下一个样品到队列。 PIE列表包含每个前体离子的m / z值和时间窗口,并且会智能生成,因此,如果MS / MS不足以识别目标峰,它将在色谱峰的顶部附近再次收集。下一次运行。因此,该策略可最大程度地提高独特MS / MS的质量和数量。当使用自动PIE采集抗体胰蛋白酶消化物和大豆水解物样品的LC-MS / MS数据时,与不使用PIE采集的数据相比,鉴定出的离子数分别增加了52%和93%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号