首页> 外文期刊>Journal of strength and conditioning research >'FUNCTIONAL' RESPIRATORY MUSCLE TRAINING DURING ENDURANCE EXERCISE CAUSES MODEST HYPOXEMIA BUT OVERALL IS WELL TOLERATED
【24h】

'FUNCTIONAL' RESPIRATORY MUSCLE TRAINING DURING ENDURANCE EXERCISE CAUSES MODEST HYPOXEMIA BUT OVERALL IS WELL TOLERATED

机译:耐力锻炼过程中的“功能性”呼吸肌训练导致整体低氧血症的发生但总体上正确定位

获取原文
获取原文并翻译 | 示例
           

摘要

Granados, J, Gillum, TL, Castillo, W, Christmas, KM, and Kuennen, MR. "Functional" respiratory muscle training during endurance exercise causes modest hypoxemia but overall is well tolerated. J Strength Cond Res 30( 3): 755- 762, 2016- A novel commercial training mask purportedly allows for combined respiratory muscle training and altitude exposure during exercise. We examined the mask's ability to deliver on this claim. Ten men completed three bouts of treadmill exercise at a matched workload ( 60% VO2peak) in a controlled laboratory environment. During exercise, the mask was worn in 2 manufacturer- defined settings ( 9,000 ft [ 9K] and 15,000 ft [ 15K]) and a Sham configuration (; 3,500 ft). Ventilation ( VE), tidal volume ( VT), respiratory rate ( RR), expired oxygen ( FEO2) and carbon dioxide ( FECO2), peripheral oxygen saturation ( SPO2), heart rate, and RPE were measured each minute during exercise, and subjects completed the Beck Anxiety Inventory ( BAI) immediately after. The mask caused a reduction in VE of similar to 20L/ min in both the 9K and 15K configurations ( p<0.001). This was due to a reduction in RR of similar to 10 b min(-1), but not VT, which was elevated by; 250 ml ( p<0.001). FEO2 was reduced and FECO2 was elevated above Sham in both 9K and 15K ( p< 0.001). V-O2 was not different across conditions ( p = 0.210), but V-CO2 trended lower at 9K ( p = 0.093) and was reduced at 15K ( p = 0.016). VE/ V-O2 was 18.3% lower than Sham at 9K and 19.2% lower at 15K. VE/ V-CO2 was 16.2% lower than Sham at 9K and 18.8% lower at 15K ( all p, 0.001). Heart rate increased with exercise ( p, 0.001) but was not different among conditions ( p = 0.285). SPO2 averaged 94% in Sham, 91% at 9K, and 89% at 15K ( p, 0.001). RPE and BAI were also higher in 9K and 15K ( p, <0.010), but there was no difference among mask conditions. The training mask caused inadequate hyperventilation that led to arterial hypoxemia and psychological discomfort, but the magnitude of these responses were small and they did not vary across mask configurations.
机译:格拉纳多斯(J),吉勒姆(Gillum),TL,卡斯蒂略(Castillo),W,圣诞节(KM)和肯恩(Kuennen),MR。在耐力运动中进行“功能性”呼吸肌训练会引起适度的低氧血症,但总体耐受性良好。 J Strength Cond Res 30(3):755-762,2016-据称,一种新型的商用训练面罩可在运动过程中结合呼吸肌训练和高原暴露。我们检查了口罩实现此要求的能力。十个人在受控的实验室环境中以相称的工作量(VO2peak为60%)完成了三轮跑步机运动。在运动过程中,将面罩戴在制造商定义的2种设置下(9,000 ft [9K]和15,000 ft [15K])和Sham配置(; 3,500 ft)。在运动过程中每分钟对受试者进行通气(VE),潮气量(VT),呼吸频率(RR),呼出氧(FEO2)和二氧化碳(FECO2),外周血氧饱和度(SPO2),心率和RPE的测量之后立即完成了贝克焦虑量表(BAI)。在9K和15K配置中,面罩导致的VE降低类似于20L / min(p <0.001)。这是由于RR降低了约10 b min(-1),但VT却没有降低,而VT却提高了; 250毫升(p <0.001)。在9K和15K中,FEO2降低,FECO2升高至Sham以上(p <0.001)。 V-O2在所有条件下均无差异(p = 0.210),但V-CO2在9K时趋于降低(p = 0.093),而在15K时则降低(p = 0.016)。 VE / V-O2在9K时比Sham低18.3%,在15K时低19.2%。 VE / V-CO2在9K时比Sham低16.2%,在15K时低18.8%(全部p,0.001)。运动使心率增加(p,0.001),但不同情况之间无差异(p = 0.285)。 Sham中的SPO2平均为94%,9K时为91%,1万5K时为89%(p,0.001)。 RPE和BAI在9K和15K中也较高(p,<0.010),但是在掩膜条件之间没有差异。训练面罩引起的通气不足,导致动脉血氧不足和心理不适,但是这些反应的幅度很小,并且在各个面罩配置中没有变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号