首页> 外文期刊>Journal of Sound and Vibration >On the selection of acoustic/vibration sensors for leak detection in plastic water pipes
【24h】

On the selection of acoustic/vibration sensors for leak detection in plastic water pipes

机译:关于用于塑料水管检漏的声/振动传感器的选择

获取原文
获取原文并翻译 | 示例
           

摘要

Leaks from buried water distribution pipes are commonly located by applying the correlation technique to two measured acoustic/vibration signals on either side of a leak. The effectiveness of the correlation technique for locating leaks in plastic pipes depends on the type of sensors used and their sensitivities. Based on an analytical model of the cross-correlation of pressure responses established in an earlier study, this paper investigates the behaviour of the cross-correlation coefficient for leak signals measured using pressure, velocity and acceleration sensors. Theoretical predictions show that a measure of pressure responses using hydrophones is effective for measurements where there is a small signal-to-noise ratio (SNR), but a sharper peak correlation coefficient can be achieved if accelerometers are used. The theoretical work is validated to some extent with test data from actual water pipes on a test site in Canada. (c) 2004 Elsevier Ltd. All rights reserved.
机译:通常通过将相关技术应用于泄漏两侧的两个测得的声音/振动信号,来确定地下供水管道的泄漏。用于定位塑料管道中泄漏的相关技术的有效性取决于所用传感器的类型及其灵敏度。基于早期研究中建立的压力响应互相关分析模型,本文研究了使用压力,速度和加速度传感器测得的泄漏信号互相关系数的行为。理论预测表明,使用水听器对压力响应进行测量对于信噪比(SNR)小的测量非常有效,但是如果使用加速度计,则可以实现更清晰的峰值相关系数。理论工作在一定程度上已通过加拿大测试站点上实际水管的测试数据得到验证。 (c)2004 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号