首页> 外文期刊>Journal of shoulder and elbow surgery >Comparison of ultrasound-guided versus blind glenohumeral injections: A cadaveric study
【24h】

Comparison of ultrasound-guided versus blind glenohumeral injections: A cadaveric study

机译:超声引导与盲人盂肱静脉注射的比较:尸体研究

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Intra-articular glenohumeral (GH) injections are important for diagnostic and therapeutic purposes. It has been suggested that ultrasound guided injections are more accurate than blind or freehand injections. This study assessed the accuracy of ultrasound-guided GH injections compared with freehand injections in fresh cadavers. Methods: The study used 80 shoulder specimens from fresh cadavers. Ultrasound guidance was used to inject radiopaque contrast in 40 shoulders, and freehand technique was used in the remaining 40. All injections were performed by 2 surgeons (A and B) through a posterior approach. After the injections, radiographs were obtained of the specimens to assess the accuracy of the injections. Results: Sixty-six of 80 (82.5%) injections were accurately administered into the GH joint. Ultrasound-guided injections were accurate in 37 of 40 specimens (92.5%) compared with freehand injections, which were accurate in only 29 of 40 specimens (72.5%; P = .02). Both surgeons independently had higher accuracy using ultrasound-guidance compared with the freehand technique (surgeon A: 90% vs 65%, P = 0.058; surgeon B: 95% vs 80%, P = 0.15). The average time for injections was 52 seconds by the freehand technique and 166 seconds using ultrasound guidance (P < 0.001). Conclusions: The data from this cadaveric study suggest that ultrasound-guided injections are more accurate at reaching the GH joint than freehand injections. The ultrasound-guided injections took substantially longer to administer. Once familiar with the technique, surgeons can expect improved accuracy and efficacy of GH joint injections using ultrasound guidance in the clinical setting.
机译:背景:关节腔盂肱(GH)注射对于诊断和治疗目的很重要。已经建议超声引导注射比盲注或徒手注射更准确。这项研究评估了新鲜尸体中超声引导的GH注射与徒手注射相比的准确性。方法:该研究使用了来自新鲜尸体的80个肩部标本。超声引导用于在40个肩部注入不透射线的对比,其余40个使用徒手技术。所有注射均由2位外科医生(A和B)通过后路进行。注射后,获得标本的射线照片以评估注射的准确性。结果:在GH关节中准确注射了六十六次(80.5%)的注射。与徒手注射相比,超声引导下的注射在40个样本中的37个(准确率为92.5%)中准确,而在40个样本中仅29个(72.5%; P = .02)准确。与徒手技术相比,两位外科医生在超声引导下均具有更高的准确性(外科医生A:90%比65%,P = 0.058;外科医生B:95%对80%,P = 0.15)。徒手技术的平均注射时间为52秒,超声引导下的平均注射时间为166秒(P <0.001)。结论:来自尸体研究的数据表明,超声引导下的注射要比徒手注射更准确地到达GH关节。超声引导的注射花费了更长的时间。一旦熟悉该技术,外科医生就可以期望在临床环境中使用超声引导提高GH关节注射的准确性和疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号